Related Experiment Video
Updated: May 5, 2026

Adjustable Stiffness, External Fixator for the Rat Femur Osteotomy and Segmental Bone Defect Models
Published on: October 9, 2014
Biomechanical comparison of hybrid external fixators
D W Lundy1, M J Albert, W C Hutton
1Department of Orthopaedic Surgery, Georgia Baptist Medical Center, Atlanta, USA.
Hybrid external fixators demonstrate comparable stiffness to conventional Ilizarov fixators for treating tibial fractures. Optimal configuration involves placing wire-to-ring connectors inside the ring for enhanced rigidity.
Area of Science:
- Orthopedic biomechanics
- Trauma surgery
- Biomaterials engineering
Background:
- Tibial fractures, particularly OTA 41-C proximal metaphyseal and shaft types, require stable fixation.
- Hybrid external fixators offer an alternative to conventional methods, but their biomechanical properties need thorough evaluation.
Purpose of the Study:
- To assess and compare the stiffness characteristics of four different hybrid external fixators against the conventional Ilizarov fixator.
- To evaluate the impact of connector placement on fixator rigidity.
Main Methods:
- Five composite tibiae were instrumented with four types of hybrid external fixators (Synthes, ACE Fischer, Howmedica Monticelli-Spinelli, Smith & Nephew Trauma Ilizarov) and a conventional Ilizarov fixator.
- Fixators underwent mechanical testing under axial compression, bending (anterior/posterior, medial/lateral), and torsion using a materials testing machine.
- Stiffness was quantified by analyzing load-deformation and torque-angle data.
Main Results:
- The Synthes and Monticelli-Spinelli fixators exhibited the highest rigidity when wire-to-ring connectors were positioned internally.
- Fixator stiffness varied by loading mode, being greatest in axial compression and lowest in posterior bending.
- Wire length was identified as a significant factor influencing overall fixator stiffness.
Conclusions:
- The tested hybrid external fixators, in their standard configurations, provide stiffness comparable to the conventional Ilizarov fixator for treating proximal tibial fractures.
- These findings support the use of hybrid external fixators as a viable option for managing complex tibial shaft and metaphyseal fractures.
More Related Videos
06:41A Minimally Invasive Model to Analyze Endochondral Fracture Healing in Mice Under Standardized Biomechanical Conditions
Published on: March 22, 2018
08:20A Reliable and Reproducible Critical-Sized Segmental Femoral Defect Model in Rats Stabilized with a Custom External Fixator
Published on: March 24, 2019