Objective:
Aortic valve replacement has been approached by standard sternotomy. We described a technique of aortic valve replacement where the aortic valve is exposed through a hemi-sternotomy. Good exposure is obtained for aortic valve surgery with standard aortic and right atrial cannulation to establish cardiopulmonary bypass (CPB).
Methods:
From October 1996 to April 1997, 19 consecutive aortic valve replacements (AVR) via hemi-sternotomy were performed by one surgeon. The results were collected and analysed prospectively. Results are expressed as mean +/- standard deviation. Nineteen patients (13 male, 6 female) had AVR with this approach. Two cases were redo AVR. The mean age was 58+/-15 years. The New York Heart Association (NYHA) class was 2.8+/-0.7.
Results:
Aortic cross clamp time was 54+/-13 min. One of six patients requiring defibrillation after reperfusion needed conversion to full sternotomy. Four patients were extubated at the conclusion of surgery. One patient died 4 h postoperatively from low cardiac output. All patients had normal valvular function demonstrated on postoperative transoesophageal echocardiography. There were no neurological events.
Conclusions:
Minimally invasive aortic valve replacement can be safely performed via hemi-sternotomy with standard equipment. Less surgical trauma to the sternum has the potential benefit of less pain and shorter intensive care and hospital stay.