Accurate time interval in repeated tonometry

O F Recep1, H Hasiripi, E Vayisoglu

  • 13rd Eye Clinic, Numune State Hospital, Ankara-Türkiye.

Acta Ophthalmologica Scandinavica
|November 24, 1998
PubMed
Summary
This summary is machine-generated.

Related Concept Videos

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Postoperative analgesia after total abdominal hysterectomy: Is the transversus abdominis plane block effective?

Nigerian journal of clinical practice·2019
Same author

Risk factors in central retinal vein occlusion an activated protein C resistance.

European journal of ophthalmology·2017
Same author

Are there any effects of Sevoflurane and Desflurane anaesthesia on blood glucose levels in acute hyperglycemic diabetic rats?

Bratislavske lekarske listy·2016
Same author

Non-penetrating deep sclerectomy in unilateral open-angle glaucoma secondary to idiopathic dilated episcleral veins.

European journal of ophthalmology·2002
Same author

Combined ocular anesthesia via a single entry.

Journal of cataract and refractive surgery·2001
Same author

Relation between corneal thickness and intraocular pressure measurement by noncontact and applanation tonometry.

Journal of cataract and refractive surgery·2001
Same journal

Expression of interleukin-6, tumour necrosis factor-alpha and nitric oxides during episodes of ocular toxoplasmosis in an HIV patient.

Acta ophthalmologica Scandinavica·2007
Same journal

Varicella chorioretinitis.

Acta ophthalmologica Scandinavica·2007
Same journal

Pseudoexfoliation in the Reykjavik Eye Study: prevalence and related ophthalmological variables.

Acta ophthalmologica Scandinavica·2007
Same journal

Solving the enigma of exfoliation glaucoma: a breakthrough in glaucoma research.

Acta ophthalmologica Scandinavica·2007
Same journal

Incidence and prevalence of pseudoexfoliations and open-angle glaucoma in northern Sweden: II. Results after 21 years of follow-up.

Acta ophthalmologica Scandinavica·2007
Same journal

Incidence and prevalence of pseudoexfoliation and open-angle glaucoma in northern Sweden: I. Baseline report.

Acta ophthalmologica Scandinavica·2007
See all related articles

For accurate intraocular pressure (IOP) measurements, allow at least 2 or 10 minutes between repeated tonometry. Shorter intervals (1, 3, 4, 5 minutes) showed statistically significant differences.

Area of Science:

  • Ophthalmology
  • Biomedical Engineering

Background:

  • Accurate intraocular pressure (IOP) measurement is crucial for diagnosing and managing glaucoma.
  • Repeated tonometry requires careful consideration of the time interval between measurements to avoid bias.

Purpose of the Study:

  • To determine the optimal time interval between successive intraocular pressure (IOP) measurements for accurate tonometry.
  • To identify intervals that minimize statistically significant variations in IOP readings.

Main Methods:

  • 270 subjects were randomized into 6 groups, each with a different time interval (1, 2, 3, 4, 5, or 10 minutes) between two Goldmann-type applanation tonometer measurements.
  • Statistical analysis using significance tests for matched observations was performed on the IOP data for each group.

Related Experiment Videos

Main Results:

  • A statistically significant difference between the first and second IOP measurements was observed at 1, 3, 4, and 5-minute intervals.
  • No statistically significant differences were found between IOP measurements at 2-minute and 10-minute intervals.

Conclusions:

  • An interval of 2 or 10 minutes between successive intraocular pressure measurements is recommended for accurate tonometry.
  • Shorter intervals may lead to artificially altered IOP readings, impacting clinical assessment.