Related Experiment Video
Updated: Aug 6, 2026

Testing of all Six Semicircular Canals with Video Head Impulse Test Systems
Published on: April 18, 2019
A screening version of the Dizziness Handicap Inventory (DHI-S)
1Division of Audiology, Henry Ford Hospital, Detroit, Michigan 48202, USA.
Objective:
This study aimed to develop a screening version of the Dizziness Handicap Inventory (DHI).
Study Design:
Three separate prospective investigations are reported that assess: 1) the equivalency of the screening version of DHI (DHI-S) for the DHI; 2) the test-retest reliability of the DHI-S; and 3) whether abnormal performance on balance function testing is associated with greater scores on the DHI-S.
Setting:
The investigation was conducted in the Balance Function Laboratory of the Division of Audiology at Henry Ford Hospital, which is a tertiary care setting.
Patients:
There were 281 consecutive patients (for investigations 1 and 2) and 45 consecutive patients (for investigation 3) seen for balance function testing.
Interventions:
There was a 1-week interval between test and retest administrations of the DHI-S.
Main Outcome Measures:
Comparability of the DHI-S for the DHI and the test-retest reliability of the DHI-S were assessed with a Pearson Product-Moment correlation coefficient. Scores on the DHI-S for patients with and without abnormal balance function tests were assessed with an analysis of variance.
Results:
Results showed that scores on the DHI-S had high comparability for the total score on the DHI (r=0.86). The short-term, test-retest reliability for the DHI was high (r=0.95). Abnormal performance on the sensory organization subtest of computerized dynamic posturography was associated with significantly greater scores on the DHI-S.
Conclusions:
Results support the contention that DHI-S is a psychometrically robust screening measure of self-perceived dizziness disability-handicap.