Vectorcardiographic loop alignment and morphologic beat-to-beat variability

L Sörnmo1

  • 1Department of Applied Electronics, Lund University, Sweden. leif.sornmo@tde.lth.se

IEEE Transactions on Bio-Medical Engineering
|December 3, 1998
PubMed
Summary
This summary is machine-generated.

Related Concept Videos

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Cardiac signal estimation based on the arterial and venous pressure signals of a hemodialysis machine.

Physiological measurement·2016
Same author

Identification of patients prone to hypotension during hemodialysis based on the analysis of cardiovascular signals.

Medical engineering & physics·2015
Same author

A modified Lewis ECG lead system for ambulatory monitoring of atrial arrhythmias.

Journal of electrocardiology·2014
Same author

Breathing pattern characterization in chronic heart failure patients using the respiratory flow signal.

Annals of biomedical engineering·2010
Same author

Computer-based detection and analysis of heart sound and murmur.

Annals of biomedical engineering·2005
Same author

Signal-averaged electrocardiography in normal newborn infants.

Pediatric cardiology·2004
Same journal

Enhancing Volumetric Imaging in Linear-Array Photoacoustic Tomography: multiview fusion with deep learning.

IEEE transactions on bio-medical engineering·2026
Same journal

Robust Rule-based Heuristic Assistance Strategy for a Semi-Active Shoulder Exoskeleton Used in Overhead Work.

IEEE transactions on bio-medical engineering·2026
Same journal

Highly Accelerated 1-mm Isotropic 3D Chemical Exchange Saturation Transfer MRI Using Wave-Co-CAIPI at 5 Tesla.

IEEE transactions on bio-medical engineering·2026
Same journal

Systematic Evaluation of Hip Exoskeleton Assistance Parameters for Enhancing Gait Stability During Ground Slip Perturbations.

IEEE transactions on bio-medical engineering·2026
Same journal

SleepConFormer: A Single-Channel EEG Framework for Sleep Staging and Consciousness Assessment in Patients with Disorders of Consciousness.

IEEE transactions on bio-medical engineering·2026
Same journal

Modeling Partial and Total Support of Left Ventricular Assist Device for Discrete Hemodynamic Control Framework.

IEEE transactions on bio-medical engineering·2026
See all related articles

Respiration can distort heart rhythm analysis. A new statistical model corrects for these movements, significantly reducing errors in subtle electrocardiogram measurements and improving accuracy.

Area of Science:

  • Cardiovascular physiology
  • Biomedical signal processing
  • Statistical modeling

Background:

  • Subtle beat-to-beat variations in electrocardiogram (ECG) morphology are crucial for understanding cardiac function.
  • Respiration-induced heart movements introduce significant noise, complicating the accurate measurement of these variations.
  • Existing methods struggle to effectively isolate intrinsic cardiac morphologic changes from respiratory artifacts.

Purpose of the Study:

  • To develop a statistical signal model to account for respiration-induced heart movements in ECG analysis.
  • To present a maximum-likelihood estimator for transformations (scaling, rotation, time synchronization) of vectorcardiographic loops.
  • To assess the performance of the proposed method in reducing morphologic variability caused by respiration.

Main Methods:

Related Experiment Videos

  • Development of a statistical signal model incorporating scaling, rotation, and time synchronization of vectorcardiographic loops.
  • Application of a maximum-likelihood estimator for parameter estimation in single and multiple loop alignment.
  • Quantitative assessment of morphologic variability before and after applying the loop alignment method.

Main Results:

  • The new method considerably reduces the impact of respiration on morphologic variability measurements.
  • Morphologic variability was reduced by an average factor of 0.53 after loop alignment.
  • Beat-to-beat measurements demonstrated strong dependence on sampling rate, with 1 kHz found to be insufficient.

Conclusions:

  • The developed statistical model effectively corrects for respiration-induced heart movements in ECG analysis.
  • Loop alignment significantly improves the accuracy of subtle morphologic variability measurements.
  • Accurate beat-to-beat analysis requires careful consideration of sampling rates, advocating for rates higher than 1 kHz.