Sensitive determination of xylenes in whole blood by capillary gas chromatography with cryogenic trapping
Abstract:
A new and sensitive method for measurement of o-, m- and p-xylenes in human whole blood by capillary gas chromatography (GC) with cryogenic trapping is presented. After heating 0.5 ml of whole blood and 0.5 ml of distilled water containing the xylenes and aniline (internal standard, I.S.) in a 4.0-ml vial at 100 degrees C for 30 min, 2 ml of the headspace vapor was drawn into a glass syringe. All vapor was introduced through the GC port into an AT-Wax middle-bore capillary column in the splitless mode at an oven temperature of 5 degrees C to trap the entire analytes, and the oven temperature was then programmed up to 180 degrees C. The present conditions gave sharp peaks for xylenes and aniline (I.S.), and low background noises for whole blood samples; the peaks of p- and m-xylenes showed about 90% separation with the AT-Wax column. As much as 41.0-46.3% of xylenes, which had been spiked to whole blood could be recovered. The calibration curves showed linearity in the range of 0.1-0.5 microg/0.5 ml of whole blood. The detection limit was estimated to be about 10 ng/0.5 ml. The coefficients of intra-day and inter-day variations for xylenes were not greater than 9.38%. The data for actual detection of xylenes in post-mortem blood of self-ignition suicide cases by the present method were also presented.
More Related Videos
Related Concept Videos
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography: Types of Detectors-II
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a column.
Gas Chromatography: Sample Injection Systems
Two primary injection methods are used...
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...