Calculation vs calibration curve for INR determination. Results of an interlaboratory proficiency scheme
W F Brien1, J C Baskerville, D A Taberner
1Division of Laboratory Hematology, St Joseph's Health Centre of London, Ontario, Canada.
Abstract:
We surveyed 271 laboratories participating in a quality assessment program to ascertain whether the use of a calibration curve for determining the international normalized ratio (INR) would improve interlaboratory accuracy and precision. Lyophilized warfarinized samples with INR values assigned through manual calibration against internationally assigned rabbit reference thromboplasts were assayed for prothrombin time. Calibration analysis on the results was performed by linear regression. In all but 1 sample, the mean INR value computed by the calibration method was closer to the "true" value than the mean for the conventional calculation method using the International Sensitivity Index (ISI); the ISI calculation consistently overestimated the true value. Interlaboratory variation decreased using the calibration method. Variation from reagent to reagent was greater than from instrument to instrument, but was reduced by the calibration method. The specificity of the ISI for instrument type did not seem to alter the findings. Use of in-house calibrators to verify the ISI improved precision but not necessarily accuracy. The formation of a stable calibration line is consistent over time, but further studies are required to confirm whether such calibration improves the accuracy and precision of INR determination in practice.
More Related Videos
08:59An Intestine/Liver Microphysiological System for Drug Pharmacokinetic and Toxicological Assessment
Published on: December 3, 2020
06:53Preparation of Food Samples Using Homogenization and Microwave-Assisted Wet Acid Digestion for Multi-Element Determination with ICP-MS
Published on: December 22, 2023
Related Concept Videos
Uncertainty in Measurement: Reading Instruments
Calibration Curves: Linear Least Squares
For data that follow a straight line, the standard method for fitting is the linear...
Calibration Curves: Correlation Coefficient
Complexometric EDTA Titration Curves
Instrument Calibration
Analytical Balance Calibration
An analytical balance measures mass and requires regular calibration to...
Glassware Calibration
Volumetric flasks: Volumetric flasks are designed to prepare aqueous solutions of precise volumes accurately with a calibration line on the neck. To calibrate a volumetric flask, it is important to fill it with distilled...