Contrast angiosonography: a technology to improve Doppler ultrasound examinations of the prostate
R G Aarnink1, H P Beerlage, J J de la Rosette
1Department of Urology, University Hospital Nijmegen, The Netherlands.
Objectives:
A feasibility study to evaluate whether analysis techniques adapted from X-ray angiography can be used to analyze the transient enhancement of prostate blood flow patterns in color Doppler maps as obtained after administering ultrasound contrast agents.
Methods:
Injections of ultrasound contrast agents were given to dogs and humans, and color Doppler blood flow patterns in fixed transverse sections through the prostate were recorded on video tape. Computer assistance of Doppler signals over time is used to evaluate the transient enhancement of flow patterns obtained with contrast-enhanced Doppler ultrasound. Results are compared to indicator dilution curve theory as used in, e.g., X-ray angiography.
Results:
Administering a contrast agent to improve color Doppler evaluation of prostate blood flow resulted in clear enhancement of Doppler signal intensities without unwanted side effects. Using the computer, the perfused area of the prostate could be obtained quantitatively over time showing profiles of individual heartbeats. Averaging the perfused area over one heartbeat resulted in an indicator dilution curve, and correlation with dilution theory indicated the feasibility of applying wash-in and wash-out analysis of contrast agents in color Doppler images.
Conclusion:
Frame-by-frame interpretation by the computer indicated the feasibility of analyzing the transient enhancement of blood flow visibility in the Doppler image over time using techniques such as wash-in and wash-out time. This technology provides researchers in the field of ultrasound evaluation of the prostate the opportunity to apply a new diagnostic tool, contrast angiosonography, in their research. This method for analysis of prostatic blood flow can be helpful in any application that affects the blood supply of the prostate such as heat treatments and hormonal treatments.
Related Concept Videos
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Ultrasonography
During an ultrasonography procedure, a handheld device called a...
Ultrasound II: Endoscopic Ultrasound and FibroScan
Endoscopic Ultrasound (EUS):
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for diagnosing...
Imaging Studies II: Ultrasonography