Filters

Daisaku Tatsumi

Showing results (1-10 of 19) with videos related to

Pageof 2
Sort By:
Nihon Hoshasen Gijutsu Gakkai Zasshi|March 3, 2012
[Optimization of multi-leaf collimator leaf offset table for a treatment planning system]Daisaku Tatsumi
Nihon Hoshasen Gijutsu Gakkai Zasshi|March 3, 2012
[A method for removing moiré artifacts from scanned images of radiochromic films: application to transmissive scanning]Daisaku Tatsumi, Shuichi Ozawa
Nihon Hoshasen Gijutsu Gakkai Zasshi|January 11, 2023
[Decomposing a Beam Profile Constancy into Energy and Symmetry Components and Its Evaluation Using an Ionization Chamber Array]Daisaku Tatsumi, Hiroshi Okuda, Yuji Yamamoto
Acta Oto-Laryngologica|February 23, 2018
Definitive re-irradiation using intensity-modulated radiation therapy in cancers of the head and neck, focusing on rare tumorsHiroshi Doi, Kenji Uemoto, Norihisa Masai, et al.
Nihon Hoshasen Gijutsu Gakkai Zasshi|January 30, 2013
[Electronic portal image device dosimetry for volumetric modulated arc therapy]Daisaku Tatsumi, Ryosei Nakada, Akinori Ienaga, et al.
Nihon Hoshasen Gijutsu Gakkai Zasshi|November 23, 2012
[Positional accuracy and quality assurance of Backup JAWs required for volumetric modulated arc therapy]Daisaku Tatsumi, Ryosei Nakada, Akinori Ienaga, et al.
Nihon Hoshasen Gijutsu Gakkai Zasshi|October 27, 2011
[Mechanical accuracy of a stereotactic irradiation system using a micro multi-leaf collimator]Daisaku Tatsumi, Ryosei Nakada, Shinichi Tsutsumi, et al.
Nihon Hoshasen Gijutsu Gakkai Zasshi|February 2, 2011
[Evaluation of new methods for removing moire artifact of radiochromic film]Daisaku Tatsumi, Ryosei Nakada, Norihisa Masai, et al.
Nihon Hoshasen Gijutsu Gakkai Zasshi|October 24, 2012
[Quality assurance procedure for assessing mechanical accuracy of a radiation field center in stereotactic radiotherapy]Daisaku Tatsumi, Akinori Ienaga, Ryosei Nakada, et al.
Reports of Practical Oncology and Radiotherapy : Journal of Greatpoland Cancer Center in Poznan and Polish Society of Radiation Oncology|May 17, 2017
Validation of the liver mean dose in terms of the biological effective dose for the prevention of radiation-induced liver damageHiroshi Doi, Norihisa Masai, Kenji Uemoto, et al.
Pageof 2

Showing results (1-10 of 19) with videos related to

Sort By:
Pageof 2
Nihon Hoshasen Gijutsu Gakkai Zasshi|March 3, 2012
[Optimization of multi-leaf collimator leaf offset table for a treatment planning system]Daisaku Tatsumi
Nihon Hoshasen Gijutsu Gakkai Zasshi|March 3, 2012
[A method for removing moiré artifacts from scanned images of radiochromic films: application to transmissive scanning]Daisaku Tatsumi, Shuichi Ozawa
Nihon Hoshasen Gijutsu Gakkai Zasshi|January 11, 2023
[Decomposing a Beam Profile Constancy into Energy and Symmetry Components and Its Evaluation Using an Ionization Chamber Array]Daisaku Tatsumi, Hiroshi Okuda, Yuji Yamamoto
Acta Oto-Laryngologica|February 23, 2018
Definitive re-irradiation using intensity-modulated radiation therapy in cancers of the head and neck, focusing on rare tumorsHiroshi Doi, Kenji Uemoto, Norihisa Masai, et al.
Nihon Hoshasen Gijutsu Gakkai Zasshi|January 30, 2013
[Electronic portal image device dosimetry for volumetric modulated arc therapy]Daisaku Tatsumi, Ryosei Nakada, Akinori Ienaga, et al.
Nihon Hoshasen Gijutsu Gakkai Zasshi|November 23, 2012
[Positional accuracy and quality assurance of Backup JAWs required for volumetric modulated arc therapy]Daisaku Tatsumi, Ryosei Nakada, Akinori Ienaga, et al.
Nihon Hoshasen Gijutsu Gakkai Zasshi|October 27, 2011
[Mechanical accuracy of a stereotactic irradiation system using a micro multi-leaf collimator]Daisaku Tatsumi, Ryosei Nakada, Shinichi Tsutsumi, et al.
Nihon Hoshasen Gijutsu Gakkai Zasshi|February 2, 2011
[Evaluation of new methods for removing moire artifact of radiochromic film]Daisaku Tatsumi, Ryosei Nakada, Norihisa Masai, et al.
Nihon Hoshasen Gijutsu Gakkai Zasshi|October 24, 2012
[Quality assurance procedure for assessing mechanical accuracy of a radiation field center in stereotactic radiotherapy]Daisaku Tatsumi, Akinori Ienaga, Ryosei Nakada, et al.
Reports of Practical Oncology and Radiotherapy : Journal of Greatpoland Cancer Center in Poznan and Polish Society of Radiation Oncology|May 17, 2017
Validation of the liver mean dose in terms of the biological effective dose for the prevention of radiation-induced liver damageHiroshi Doi, Norihisa Masai, Kenji Uemoto, et al.