Comparison of nonionic contrast agents iohexol and iotrolan for cisternal myelography in dogs

H van Bree1, B Van Rijssen, L Van Ham

  • 1Small Animal Clinic, State University of Ghent, Belgium.

Insights

Iohexol and iotrolan were compared for canine cisternal myelography. Iotrolan provided superior radiographic quality over time compared to iohexol, with no significant adverse effects noted for either contrast agent.

Area of Science:

  • Veterinary Radiology
  • Diagnostic Imaging
  • Neurology

Background:

  • Cisternal myelography is a diagnostic procedure used in veterinary medicine to visualize the spinal cord.
  • Contrast agents are essential for effective myelography, but their safety and efficacy can vary.
  • Iohexol and iotrolan are non-ionic, low-osmolar contrast media used in various imaging applications.

Purpose of the Study:

  • To compare the safety and efficacy of iohexol versus iotrolan for canine cisternal myelography.
  • To evaluate the impact of these contrast agents on cerebrospinal fluid (CSF) parameters.
  • To assess the radiographic quality and duration of visualization provided by each agent.

Main Methods:

  • Six dogs underwent cisternal myelography with both iohexol and iotrolan, with a 6-week interval between procedures (each dog served as its own control).
  • Cerebrospinal fluid (CSF) was collected pre-injection and at 1, 3, 7, and 14 days post-injection for cytologic and chemical analysis.
  • Radiographic quality was assessed over time, and dogs were monitored for adverse events like seizures.

Main Results:

  • No significant changes in CSF leucocyte count or glucose concentration were observed for either contrast agent.
  • Iohexol showed a transient increase in CSF protein and lactate dehydrogenase activity, while iotrolan did not.
  • Radiographic quality degraded over time for both agents, but iotrolan maintained superior visualization for longer periods compared to iohexol.

Conclusions:

  • Both iohexol and iotrolan are safe for canine cisternal myelography, with no significant adverse neurological effects or pathological changes observed.
  • Iotrolan demonstrates superior and more sustained radiographic quality compared to iohexol in canine cisternal myelography.
  • Iotrolan may be a preferred contrast agent for canine cisternal myelography when prolonged visualization is required.