Related Experiment Video
Updated: Aug 24, 2026

Non-invasive Optical Imaging of the Lymphatic Vasculature of a Mouse
Published on: March 8, 2013
Comparison of nonionic contrast agents iohexol and iotrolan for cisternal myelography in dogs
H van Bree1, B Van Rijssen, L Van Ham
1Small Animal Clinic, State University of Ghent, Belgium.
Insights
Iohexol and iotrolan were compared for canine cisternal myelography. Iotrolan provided superior radiographic quality over time compared to iohexol, with no significant adverse effects noted for either contrast agent.
Area of Science:
- Veterinary Radiology
- Diagnostic Imaging
- Neurology
Background:
- Cisternal myelography is a diagnostic procedure used in veterinary medicine to visualize the spinal cord.
- Contrast agents are essential for effective myelography, but their safety and efficacy can vary.
- Iohexol and iotrolan are non-ionic, low-osmolar contrast media used in various imaging applications.
Purpose of the Study:
- To compare the safety and efficacy of iohexol versus iotrolan for canine cisternal myelography.
- To evaluate the impact of these contrast agents on cerebrospinal fluid (CSF) parameters.
- To assess the radiographic quality and duration of visualization provided by each agent.
Main Methods:
- Six dogs underwent cisternal myelography with both iohexol and iotrolan, with a 6-week interval between procedures (each dog served as its own control).
- Cerebrospinal fluid (CSF) was collected pre-injection and at 1, 3, 7, and 14 days post-injection for cytologic and chemical analysis.
- Radiographic quality was assessed over time, and dogs were monitored for adverse events like seizures.
Main Results:
- No significant changes in CSF leucocyte count or glucose concentration were observed for either contrast agent.
- Iohexol showed a transient increase in CSF protein and lactate dehydrogenase activity, while iotrolan did not.
- Radiographic quality degraded over time for both agents, but iotrolan maintained superior visualization for longer periods compared to iohexol.
Conclusions:
- Both iohexol and iotrolan are safe for canine cisternal myelography, with no significant adverse neurological effects or pathological changes observed.
- Iotrolan demonstrates superior and more sustained radiographic quality compared to iohexol in canine cisternal myelography.
- Iotrolan may be a preferred contrast agent for canine cisternal myelography when prolonged visualization is required.
Abstract:
During this investigation, the use of iohexol was compared with iotrolan for canine cisternal myelography. Iohexol and iotrolan myelography was done in 6 dogs by cisternal puncture with a 6-week interval between both procedures; each dog served as its own control. Cerebrospinal fluid (CSF) was collected for baseline analysis from each dog immediately before the contrast agent was injected. Cerebrospinal fluid samples were obtained at 1, 3, 7, and 14 days after injection of each contrast medium for cytologic and chemical analysis. Total CSF leucocyte count and glucose concentration did not change significantly in comparison with baseline data in any of the samples. After the injection of iohexol, protein concentration increased significantly in the 24-hour sample, and lactate dehydrogenase activity increased significantly in the 3-day sample. Significant difference was not found between the different samples collected at 1, 3, 7, and 14 days, compared with both contrast media. None of the dogs had seizure activity during a 5-hour postmyelographic observation period. Pathologic changes were not found by gross or microscopic examination of the spinal cord. Although a degradation in time of radiographic quality of all myelograms took place, the average radiographic score decreased more rapidly with iohexol. The average score at 90 minutes with iotrolan was comparable with the score at 45 minutes with iohexol, and the average score at 150 minutes with iotrolan was better than the score at 90 minutes with iohexol. At 5 and 10 minutes after cisternal injection, no significant difference was observable between the myelograms, but from 45 minutes onward, myelograms with iotrolan were superior.
More Related Videos
Related Concept Videos
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies III: Computed Tomography

