Related Experiment Video
Updated: Jun 12, 2026

Isolation of Human Atrial Myocytes for Simultaneous Measurements of Ca2+ Transients and Membrane Currents
Published on: July 3, 2013
Intrahissian anisotropy and second degree type I block
Jeffrey L Williams1, David Lugg, Robert Gray
1Good Samaritan Health System, Lebanon Cardiology Associates, 775 Norman Drive, Lebanon, PA 17042.
Insights
This study reports a rare case of a patient experiencing both intrahissian Wenckebach and anisotropy, leading to syncope. A dual-chamber pacemaker successfully treated these cardiac conduction abnormalities.
Area of Science:
- Cardiology
- Electrophysiology
- Cardiac Electrophysiology
Background:
- Syncope can result from various cardiac conduction abnormalities.
- Intrahissian Wenckebach and anisotropy are distinct electrophysiological phenomena affecting cardiac conduction.
Purpose of the Study:
- To report the first documented case of co-occurring intrahissian Wenckebach and anisotropy in a single patient presenting with syncope.
- To highlight the diagnostic and therapeutic approach for complex conduction disorders.
Main Methods:
- Invasive electrophysiologic study was performed to evaluate the cause of syncope.
- Diagnostic criteria for intrahissian Wenckebach and anisotropy were applied.
- Dual-chamber pacemaker implantation was performed.
Main Results:
- Electrophysiologic evaluation confirmed the presence of both intrahissian Wenckebach and anisotropy in the patient.
- The patient experienced multiple episodes of witnessed syncope attributed to these conduction abnormalities.
- Dual-chamber pacemaker implantation was technically successful and without immediate complications.
Conclusions:
- The simultaneous occurrence of intrahissian Wenckebach and anisotropy is a rare but significant finding in patients with syncope.
- Electrophysiologic studies are crucial for diagnosing complex conduction disturbances.
- Pacemaker implantation is an effective treatment for syncope caused by these conditions.
Abstract:
A 79 year old female presents for evaluation of multiple episodes of witnessed syncope. Invasive electrophysiologic evaluation revealed evidence of both intrahissian Wenckebach and anisotropy. This is the first report documenting both phenomena in the same patient. The patient underwent a dual-chamber pacemaker implantation without complication.
More Related Videos
08:10Estimating Bilateral Atrial Function by Cardiovascular Magnetic Resonance Feature Tracking in Patients with Paroxysmal Atrial Fibrillation
Published on: July 20, 2022
11:00Experimental Investigation of Secondary Flow Structures Downstream of a Model Type IV Stent Failure in a 180° Curved Artery Test Section
Published on: July 19, 2016
Related Concept Videos
Dysrhythmias IV: Characteristics of Bradyarrhythmias
Disturbances in Heart Rhythm
Arrhythmias are categorized by their speed, rhythm, and origin. A slow heart...
Antiarrhythmic Drugs: Class I Agents as Sodium Channel Blockers
Class 1A Antiarrhythmic Drugs: These drugs work by moderately blocking sodium channels,...
Relation between Poisson's ratio, Modulus of Elasticity and Modulus of Rigidity
Angina II: Classification
Antiarrhythmic Drugs: Class II Agents as β-Adrenergic Blockers