Skin Surface Temperatures Measured by Thermal Imaging Aid in the Diagnosis of Cellulitis

Lauren N Ko1, Adam B Raff2, Anna C Garza-Mayers1

  • 1Department of Dermatology, Massachusetts General Hospital, Harvard Medical School, Boston, Massachusetts, USA.

Insights

Skin temperature differences can help diagnose cellulitis. A temperature increase of 0.47°C or more between affected and unaffected skin accurately identifies cellulitis, distinguishing it from pseudocellulitis.

Area of Science:

  • Dermatology
  • Medical Imaging
  • Biomedical Engineering

Background:

  • Cellulitis is a common skin infection characterized by warmth, but this symptom is not specific.
  • Differentiating cellulitis from pseudocellulitis is crucial for appropriate treatment and avoiding unnecessary antibiotics.
  • Skin surface temperature measurement using thermal imaging offers a potential objective tool for diagnosis.

Purpose of the Study:

  • To assess the diagnostic utility of skin surface temperature in distinguishing cellulitis from pseudocellulitis.
  • To develop and validate a predictive model for cellulitis diagnosis based on temperature differentials.

Main Methods:

  • Adult patients with suspected cellulitis were enrolled and randomized to dermatology consultation or standard care.
  • Thermal images of affected and unaffected skin were captured for temperature analysis.
  • A logistic regression model was developed using temperature data from the dermatology consultation group and validated in the standard care group.

Main Results:

  • Cellulitis patients exhibited a significantly greater temperature difference (3.7°C) between affected and unaffected skin compared to pseudocellulitis patients (0.2°C).
  • A temperature difference threshold of 0.47°C demonstrated high sensitivity (96.6%) and accuracy (87.5%) for cellulitis diagnosis.
  • The validated model correctly diagnosed 100% of cellulitis cases and 50% of pseudocellulitis cases.

Conclusions:

  • Skin surface temperature measurement is a valuable, non-invasive tool for differentiating cellulitis from pseudocellulitis.
  • A simple temperature difference threshold can significantly aid in the accurate diagnosis of cellulitis.
  • This method can potentially improve diagnostic accuracy and guide treatment decisions in emergency settings.

Related Concept Videos

Temperature Measurement Sites01:14

Temperature Measurement Sites

A thermometer measures body temperature. The common sites for measuring body temperature are the oral cavity, axillary region, temporal artery, and skin surface, such as the forehead, abdomen, and axilla. True core body temperature is assessed in the rectum, tympanic membrane, pulmonary artery, esophagus, and urinary bladder.
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
3.6K
Equipments Used to Measure Body Temperature01:13

Equipments Used to Measure Body Temperature

Body temperature can be assessed using various devices and measured in Celsius or Fahrenheit.
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
1.9K
Assessing Body Temperature - Temporal Artery01:19

Assessing Body Temperature - Temporal Artery

Here is a stepwise guide to assessing the body temperature at the temporal artery using a temporal artery thermometer
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.  
Step 3: Assess the patient's...
1.3K
Assessing Body Temperature - Rectal01:27

Assessing Body Temperature - Rectal

Rectal temperature measurement is considered the most precise method for assessing core body temperature and typically registers higher than oral temperature. For adults, the rectal thermometer should be inserted 1 to 1.5 inches into the rectum to obtain the most accurate reading.
Follow these steps for rectal temperature assessment:
Step 1: Perform hand hygiene and don clean gloves to prevent cross-infection.
Step 2: Position the patient in a side-lying position to better visualize the rectal...
13.1K
Assessing Body Temperature - Axilla01:14

Assessing Body Temperature - Axilla

Procedural Guide for Assessing Axillary Body Temperature using a Digital Thermometer:
Step 1: Perform hand hygiene and put on clean gloves to maintain infection control and prevent cross-contamination.
Step 2: Prepare the patient by explaining the procedure to ensure understanding and cooperation. Ensure privacy, expose the axilla, and inform the patient that minimal movement is crucial for an accurate reading.
Step 3: Adjust the patient’s clothing to expose only the axilla. It minimizes...
1.5K
Assessing Body Temperature - Oral01:14

Assessing Body Temperature - Oral

Here are the steps to accurately measure oral temperature using an electronic thermometer:
Step 1:
Start by practicing proper hand hygiene to prevent the spread of microorganisms.
Step 2:
Take the thermometer out of the charging unit, switch it on, and wait for the ready sign.
Step 3:
Gently slide the probe cover until a click is heard. This simple action prevents cross-contamination and ensures the correct placement of the probe cover.
Step 4:
Instruct the patient to open their mouth and place...
1.7K