Related Experiment Video
Updated: Jul 31, 2025

Whole-animal Imaging and Flow Cytometric Techniques for Analysis of Antigen-specific CD8+ T Cell Responses after Nanoparticle Vaccination
Published on: April 29, 2015
Flow cytometry as an integrative method for the evaluation of vaccine immunogenicity: A validation approach
Elena Gianchecchi1, Alessandro Torelli2, Pietro Piu1
1VisMederi S.r.l., Siena, Italy.
Insights
This study presents a validated approach for flow cytometry assays to ensure reliable human immune response data in clinical trials. It addresses the need for standardized methods in evaluating vaccine immunogenicity.
Area of Science:
- Immunology
- Bioanalytical Sciences
- Clinical Research
Background:
- Reliable evaluation of human immune responses in clinical trials requires well-characterized and validated bioanalytical assays.
- Standardization recommendations for flow cytometry exist, but definitive guidelines for clinical applications are lacking.
Purpose of the Study:
- To provide a comprehensive validation approach for flow cytometry assays.
- To demonstrate the applicability of validated flow cytometry for clinical research and vaccine immunogenicity evaluation.
Main Methods:
- Validation of flow cytometry assays was performed by examining key parameters.
- Parameters included linearity, relative accuracy, repeatability, intermediate precision, range, detection limits, and specificity.
Main Results:
- The presented validation approach systematically assesses critical assay performance characteristics.
- Demonstrated the suitability of flow cytometry for reliable measurement of immune responses in clinical settings.
Conclusions:
- A robust validation strategy is essential for flow cytometry assays used in clinical research.
- Validated flow cytometry can serve as a reliable method for assessing vaccine immunogenicity.
Abstract:
The applied bioanalytical assays used for the evaluation of human immune responses from samples collected during clinical trials must be well characterized, fully validated and properly documented to provide reliable results. Even though recommendations for the standardization of flow cytometry instrumentation and assay validation for its clinical application have been published by several organizations, definitive guidelines are not available yet. The aim of the present paper is to provide a validation approach for flow cytometry, examining parameters such as linearity, relative accuracy, repeatability, intermediate precision, range and detection limits and specificity, in order to demonstrate and document its applicability for clinical research purposes and its possible use as one of the methods for the evaluation of vaccine immunogenicity.
More Related Videos
09:37Detection of Polyfunctional T Cells in Children Vaccinated with Japanese Encephalitis Vaccine via the Flow Cytometry Technique
Published on: September 23, 2022
09:03Rapid In Vivo Assessment of Adjuvant's Cytotoxic T Lymphocytes Generation Capabilities for Vaccine Development
Published on: June 19, 2018