Longitudinal Assessment of Fluorescence Stability Shows Fluorescence Intensity Decreases Over Time: Implications for

Sean C Sweat1,2,3, Sarah P R Berg1, Tenzin Kunkhyen1

  • 1Department of Neurobiology, University of Pittsburgh, Pittsburgh PA 15213.

Insights

Immunohistochemistry (IHC) signal intensity can decrease over six weeks. Antibody choice and staining method impact fluorescence stability, affecting data reliability.

Area of Science:

  • Biomedical Sciences
  • Microscopy Techniques
  • Immunohistochemistry

Background:

  • Immunohistochemistry (IHC) is a crucial technique in biological and clinical research.
  • Reliable IHC staining requires careful optimization, but signal stability over time is understudied.
  • Signal intensity changes can significantly impact data interpretation and scientific conclusions.

Purpose of the Study:

  • To investigate the stability of IHC fluorescence signal intensity over a six-week period.
  • To determine factors influencing signal decay in IHC staining.
  • To provide recommendations for best practices in imaging fluorescently labeled samples.

Main Methods:

  • Assessed fluorescence intensity stability over six weeks using widefield and confocal microscopy.
  • Evaluated the influence of primary antibody, secondary antibody, and antibody combinations.
  • Compared chemical staining with IHC staining methods.

Main Results:

  • Fluorescence intensity significantly decreased over the six-week assessment period.
  • Signal decay was influenced by the specific primary and secondary antibodies used.
  • The choice of antibody combination and staining method (chemical vs. IHC) affected the extent of signal loss.

Conclusions:

  • IHC signal intensity is not permanently stable and can decrease over time.
  • Careful selection of antibodies and consistent imaging protocols are essential for reliable IHC data.
  • Adhering to best practices in imaging fluorescent staining ensures accurate quantification and interpretation.

Related Concept Videos

Protein Dynamics in Living Cells01:19

Protein Dynamics in Living Cells

Different fluorescence-based techniques are used to study the protein dynamics in living cells. These techniques include FRAP, FRET, and PET.
Fluorescent recovery after photobleaching (FRAP) is a fluorescent-protein-based detection technique used to quantify protein movement rates within the cell. This method exposes a small portion of the cell to an intense laser beam. The laser beam causes permanent photobleaching of the fluorophore-tagged proteins in the exposed region. As the bleached...
2.6K
Two-Dimensional Microscopy in Microbiology01:29

Two-Dimensional Microscopy in Microbiology

Two-dimensional (2D) microscopy encompasses a range of optical techniques that capture images within a single focal plane, offering detailed representations of microscopic structures. These techniques are essential in biological and medical research, enabling the visualization of cellular and subcellular structures with different levels of contrast and specificity.There are several major types of 2D microscopy, each with strengths and applications.Bright-Field MicroscopyBright-field microscopy...
1.0K
Fluorescence and Phosphorescence: Instrumentation01:25

Fluorescence and Phosphorescence: Instrumentation

Fluorometers and spectrofluorometers are two types of instruments used for measuring molecular fluorescence. These instruments differ in how they select excitation and emission wavelengths and the type of light sources they utilize. Fluorometers use absorption interference filters to choose excitation and emission wavelengths. The excitation source in a fluorometer is typically a low-pressure mercury vapor lamp that emits intense lines distributed throughout the ultraviolet and visible regions.
1.4K