Intracellular magnetic labeling of lymphocytes for in vivo trafficking studies

U Schoepf1, E M Marecos, R J Melder

  • 1Center for Molecular Imaging Research, Massachusetts General Hospital, Boston 02114, USA.

Biotechniques
|June 13, 1998
PubMed

Insights

Researchers developed a method to label lymphocytes with superparamagnetic particles for magnetic resonance imaging (MRI). This technique allows for non-invasive tracking of lymphocyte trafficking in vivo without affecting cell viability or distribution.

Area of Science:

  • Biomedical Imaging
  • Cell Biology
  • Nanotechnology

Background:

  • Observing lymphocyte adhesion and trafficking in vivo over extended periods presents significant challenges.
  • Current methods for tracking lymphocytes lack the resolution and non-invasive capabilities required for dynamic in vivo studies.

Purpose of the Study:

  • To develop and validate a method for magnetically labeling lymphocytes using superparamagnetic particles.
  • To assess the feasibility of using magnetic resonance imaging (MRI) to detect and track these labeled lymphocytes in vitro and in vivo.
  • To evaluate the impact of the labeling process on lymphocyte viability, function, and biodistribution.

Main Methods:

  • Developed a lymphocyte labeling technique utilizing fluid-phase endocytosis of biocompatible superparamagnetic nanoparticles.
  • Quantified particle uptake per cell and assessed cell viability and retention of the label for up to 3 days.
  • Evaluated the effect of labeling on lymphocyte adhesion to endothelial cells and assessed particle-mediated cytotoxicity.
  • Determined the MRI detection threshold for labeled lymphocytes in phantom experiments.
  • Administered labeled lymphocytes intravenously to rats and tracked their biodistribution using MRI, comparing it to unlabeled cells.

Main Results:

  • Lymphocyte labeling achieved a maximum uptake of 0.11 ng Fe/cell (5 x 10^6 particles/lymphocyte) with stable label retention and full viability for at least 3 days.
  • Labeled lymphocytes exhibited adhesion to endothelial cells comparable to unlabeled cells, indicating no alteration in adhesion protein expression.
  • No particle-mediated cytotoxicity was observed.
  • The MRI detection limit was 2.5 x 10^6 cells/30 microL.
  • In vivo studies showed labeled lymphocytes accumulated in spleen, lymph nodes, and liver similarly to unlabeled cells, with spleen accumulation being detectable by MRI.

Conclusions:

  • Intracellular lymphocyte labeling with superparamagnetic particles is a feasible technique.
  • The labeling process does not adversely affect lymphocyte viability or their natural biodistribution.
  • MRI can successfully detect magnetically labeled lymphocytes in vivo, enabling non-invasive tracking of lymphocyte trafficking.