Related Experiment Video
Updated: Aug 8, 2026

Monitoring Dendritic Cell Migration using 19F / 1H Magnetic Resonance Imaging
Published on: March 20, 2013
Intracellular magnetic labeling of lymphocytes for in vivo trafficking studies
U Schoepf1, E M Marecos, R J Melder
1Center for Molecular Imaging Research, Massachusetts General Hospital, Boston 02114, USA.
Insights
Researchers developed a method to label lymphocytes with superparamagnetic particles for magnetic resonance imaging (MRI). This technique allows for non-invasive tracking of lymphocyte trafficking in vivo without affecting cell viability or distribution.
Area of Science:
- Biomedical Imaging
- Cell Biology
- Nanotechnology
Background:
- Observing lymphocyte adhesion and trafficking in vivo over extended periods presents significant challenges.
- Current methods for tracking lymphocytes lack the resolution and non-invasive capabilities required for dynamic in vivo studies.
Purpose of the Study:
- To develop and validate a method for magnetically labeling lymphocytes using superparamagnetic particles.
- To assess the feasibility of using magnetic resonance imaging (MRI) to detect and track these labeled lymphocytes in vitro and in vivo.
- To evaluate the impact of the labeling process on lymphocyte viability, function, and biodistribution.
Main Methods:
- Developed a lymphocyte labeling technique utilizing fluid-phase endocytosis of biocompatible superparamagnetic nanoparticles.
- Quantified particle uptake per cell and assessed cell viability and retention of the label for up to 3 days.
- Evaluated the effect of labeling on lymphocyte adhesion to endothelial cells and assessed particle-mediated cytotoxicity.
- Determined the MRI detection threshold for labeled lymphocytes in phantom experiments.
- Administered labeled lymphocytes intravenously to rats and tracked their biodistribution using MRI, comparing it to unlabeled cells.
Main Results:
- Lymphocyte labeling achieved a maximum uptake of 0.11 ng Fe/cell (5 x 10^6 particles/lymphocyte) with stable label retention and full viability for at least 3 days.
- Labeled lymphocytes exhibited adhesion to endothelial cells comparable to unlabeled cells, indicating no alteration in adhesion protein expression.
- No particle-mediated cytotoxicity was observed.
- The MRI detection limit was 2.5 x 10^6 cells/30 microL.
- In vivo studies showed labeled lymphocytes accumulated in spleen, lymph nodes, and liver similarly to unlabeled cells, with spleen accumulation being detectable by MRI.
Conclusions:
- Intracellular lymphocyte labeling with superparamagnetic particles is a feasible technique.
- The labeling process does not adversely affect lymphocyte viability or their natural biodistribution.
- MRI can successfully detect magnetically labeled lymphocytes in vivo, enabling non-invasive tracking of lymphocyte trafficking.
Abstract:
Lymphocyte adhesion and trafficking is difficult to observe in vivo over time. We used magnetic resonance imaging (MRI) to identify magnetically labeled lymphocytes in phantom experiments and in tissue. A method of lymphocyte labeling was developed that is based on fluid-phase endocytosis of nanometer-sized biocompatible superparamagnetic particles. The maximum cell uptake in culture was 0.11 ng Fe/cell corresponding to 5 x 10(6) particles/lymphocyte. Cells stably retained the label and were fully viable for at least 3 days. Labeled lymphocytes showed adhesion to human endothelial cells similar to unlabeled cells, indicating no effect of labeling on cell surface expression of adhesion proteins. No particle-mediated cytotoxicity could be observed. The detection threshold of MRI for detecting labeled lymphocytes in the current study was 2.5 x 10(6) cells/30 microL sampling volume. Following intravenous injection of labeled lymphocytes into rats, cells accumulated in spleen, lymph nodes and liver with a similar bio-distribution as unlabeled cells. Lymphocyte accumulation in the spleen resulted in MRI signal intensity changes readily detectable by MRI. These findings suggest that intracellular lymphocyte labeling with superparamagnetic particles is feasible, does not alter the viability or tissue distribution of labeled cells and allows the detection of labeled lymphocytes by MRI.