A High-Performance Anti-Noise Algorithm for Arrhythmia Recognition

Affiliations
  • 1School of Electronic and Information Engineering (SEIE), Zhuhai College of Science and Technology, Zhuhai 519041, China.
  • 2College of Communication Engineering, Jilin University, Changchun 130012, China.

Abstract

In recent years, the incidence of cardiac arrhythmias has been on the rise because of changes in lifestyle and the aging population. Electrocardiograms (ECGs) are widely used for the automated diagnosis of cardiac arrhythmias. However, existing models possess poor noise robustness and complex structures, limiting their effectiveness. To solve these problems, this paper proposes an arrhythmia recognition system with excellent anti-noise performance: a convolutionally optimized broad learning system (COBLS). In the proposed COBLS method, the signal is convolved with blind source separation using a signal analysis method based on high-order-statistic independent component analysis (ICA). The constructed feature matrix is further feature-extracted and dimensionally reduced using principal component analysis (PCA), which reveals the essence of the signal. The linear feature correlation between the data can be effectively reduced, and redundant attributes can be eliminated to obtain a low-dimensional feature matrix that retains the essential features of the classification model. Then, arrhythmia recognition is realized by combining this matrix with the broad learning system (BLS). Subsequently, the model was evaluated using the MIT-BIH arrhythmia database and the MIT-BIH noise stress test database. The outcomes of the experiments demonstrate exceptional performance, with impressive achievements in terms of the overall accuracy, overall precision, overall sensitivity, and overall F1-score. Specifically, the results indicate outstanding performance, with figures reaching 99.11% for the overall accuracy, 96.95% for the overall precision, 89.71% for the overall sensitivity, and 93.01% for the overall F1-score across all four classification experiments. The model proposed in this paper shows excellent performance, with 24 dB, 18 dB, and 12 dB signal-to-noise ratios.

Related Concept Videos

JoVE Research Video for Disturbances in Heart Rhythm 01:28

337

Arrhythmia or dysrhythmia refers to an abnormal heart rhythm caused by a defect in the heart's conduction system. It can cause the heart to beat irregularly, too quickly, or too slowly, leading to symptoms like chest pain, shortness of breath, and fainting. Factors such as stress, caffeine, alcohol, nicotine, cocaine, certain drugs, congenital defects, diseases, and electrolyte abnormalities can trigger arrhythmias.
Arrhythmias are categorized by their speed, rhythm, and origin. A slow…

JoVE Research Video for Mechanism of Cardiac Arrhythmias 01:28

672

Arrhythmias are irregular heart rhythms occurring when the heart's electrical impulses become abnormal. These disturbances can lead to various symptoms, depending on their severity and the underlying cause. Some common factors contributing to arrhythmias include hypoxia, ischemia, electrolyte imbalances, excessive catecholamine exposure, drug toxicity, and muscle overstretching. Arrhythmias can be classified into two main types based on the rate and site of origin of abnormal heart rhythms.

JoVE Research Video for Pulse rhythm 01:30

635

Pulse rhythm refers to the pattern of pulsations within specific intervals, offering valuable insights into the regularity or irregularity of the heart's beats as observed through the pattern of pulsation within specific intervals. A regular pulse exhibits a consistent heart rate with uniform waveforms and pulsation force, variations of which can be classified as normal, weak, or bounding.
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac…

JoVE Research Video for ECG Interpretation of Arrhythmias I: Sinus Arrhythmias 01:16

46

Arrhythmias are disturbances in the heart's rhythm that lead to abnormal heartbeats. These irregularities can originate from different parts of the heart and are classified based on their origin and nature.
Types of Arrhythmias
Sinus Node Arrhythmias
Sinus Bradycardia: Originating from the sinoatrial (SA) node, sinus bradycardia involves slower impulses, resulting in a heart rate of less than 60 beats per minute (bpm). Causes include sleep, vagal stimulation, beta-blockers, hypothyroidism,…

JoVE Research Video for Instrumentation Amplifier 01:25

228

An electrocardiography (ECG) machine is an essential piece of medical equipment used to monitor the electrical activity of the heart. It operates by detecting small electrical changes on the skin that result from the depolarization of the heart muscle during each heartbeat. However, these signals are in the microvolt range and can be easily overwhelmed by noise or interference.
To overcome this challenge, an ECG machine utilizes an instrumentation amplifier. This specialized amplifier is…