Method of Equivalent Error as a Criterion of the Assessment of the Algorithms Used for Estimation of Synchrophasor Parameters Taken from the Power System

Affiliations
  • 1Institute of Electrical Power Engineering, Lodz University of Technology, Stefanowskiego 20, 90-537 Lodz, Poland.

Abstract

The development of digital techniques in control engineering leads to the creation of innovative algorithms for measuring specific parameters. In the field of electric power engineering these parameters may be amplitude, phase and frequency of voltage or current occurring in the analyzed electric grid. Thus, the algorithms mentioned, applied in relation to the quoted parameters, may provide precise and reliable measurement results in the electric grid as well as ensure better grid monitoring and security. Signal analysis regarding its identification due to the type of interference is very difficult because the multitude of information obtained is very large. In order to indicate the best method for determining errors in measuring synchronous parameters of the measured current or voltage waveforms, the authors propose in this paper a new form of one error for all testing functions, which is called an equivalent error. This error is determined for each error’s value defined in the applicable standards for each of selected 15 methods. The use of the equivalent error algorithm is very helpful in identifying a group of methods whose operation is satisfactory in terms of measurement accuracy for various types of disturbances (both in the steady state and in the dynamic state) that may occur in the power grid. The results are analyzed for phasor measurement unit (PMU) devices of class P (protection) and M (measurement).

Related Concept Videos

JoVE Research Video for Simplified Synchronous Machine Model 01:30

56

The Synchronous Machine Model is a fundamental tool in analyzing and ensuring the transient stability of power systems. This model simplifies the representation of a synchronous machine under balanced three-phase positive-sequence conditions, assuming constant excitation and ignoring losses and saturation. The model is pivotal for understanding the behavior of synchronous generators connected to a power grid, particularly during transient events.
In this model, each generator is connected to a…

JoVE Research Video for Power System Three-Phase Short Circuits 01:21

25

Determining the subtransient fault current in a power system involves representing transformers by their leakage reactances, transmission lines by their equivalent series reactances, and synchronous machines as constant voltage sources behind their subtransient reactances. In this analysis, certain elements are excluded, such as winding resistances, series resistances, shunt admittances, delta-Y phase shifts, armature resistance, saturation, saliency, non-rotating impedance loads, and small…

JoVE Research Video for Routh-Hurwitz Criterion I 01:15

32

Consider an electrical power grid, where stability is essential to prevent blackouts. The Routh-Hurwitz criterion is a valuable tool for assessing system stability under varying load conditions or faults. By analyzing the closed-loop transfer function, the Routh-Hurwitz criterion helps determine whether the system remains stable.
To apply the Routh-Hurwitz criterion, a Routh table is constructed. The table's rows are labeled with powers of the complex frequency variable s, starting from the…

JoVE Research Video for Multimachine Stability 01:25

37

Multimachine stability analysis is crucial for understanding the dynamics and stability of power systems with multiple synchronous machines. The objective is to solve the swing equations for a network of M machines connected to an N-bus power system.
In analyzing the system, the nodal equations represent the relationship between bus voltages, machine voltages, and machine currents. The nodal equation is given by:

V is the N-vector of bus voltages, E is the M-vector of machine voltages, I is…

JoVE Research Video for Fast Decoupled and DC Powerflow 01:24

61

The fast decoupled power flow method addresses contingencies in power system operations, such as generator outages or transmission line failures. This method provides quick power flow solutions, essential for real-time system adjustments. Fast decoupled power flow algorithms simplify the Jacobian matrix by neglecting certain elements, leading to two sets of decoupled equations:

 These simplifications reduce the computational burden significantly compared to the full Newton-Raphson method….

JoVE Research Video for The Power Flow Problem and Solution 01:26

47

Power flow problem analysis is fundamental for determining real and reactive power flows in network components, such as transmission lines, transformers, and loads. The power system's single-line diagram provides data on the bus, transmission line, and transformer. Each bus k in the system is characterized by four key variables: voltage magnitude Vk​, phase angle δk​, real power Pk​, and reactive power Qk​. Two of these four variables are inputs, while the…