使用基于变压器的模型预测NADES的形成
Lucas B Ayres1, Federico J V Gomez2, Maria Fernanda Silva2
1Department of Chemistry, Clemson University, 211 S. Palmetto Blvd, Clemson, SC, 29634, USA.
Scientific reports
|February 22, 2024
概括
机器学习预测了用于更绿色化学的新型天然深度环保溶剂 (NADES). 这种方法加速了新型,稳定的NADES混合物的发现,促进了制药和农业应用.
科学领域:
- 绿色化学 绿色化学
- 计算化学计算化学
- 材料科学 材料科学 材料科学
背景情况:
- 在各种行业中,天然深层欧特溶剂 (NADES) 为传统有机溶剂提供了可持续的替代品.
- 目前的NADES开发严重依赖实证方法,限制了新混合物的发现.
- 需要采用数据驱动的方法来克服传统NADES发现的局限性.
研究的目的:
- 开发一种机器学习模型,用于预测稳定的NADES的形成.
- 加速发现和设计具有所需性质的新NADES.
- 在NADES开发中减少对经验方法的依赖.
主要方法:
- 使用基于变压器的神经网络,利用自然语言处理技术.
- 该模型在一般化学数据 (SMILES) 上进行了预训练,并为稳定的NADES形成的二元分类进行了微调.
- 该方法适应了语言学习策略,以在有限的数据和计算资源的情况下有效识别模式.
主要成果:
- 该算法成功地从自然化合物数据库中预测了337种新的稳定菌混合物.
- 该模型表明,它能够预测纳德斯的成分和摩尔比率,其中包含了新型分子.
- 验证包括之前报告的NADES和开发新的含伊布洛芬溶剂.
结论:
- 拟议的机器学习策略显著提高了NADES的预测和发现.
- 这种方法有可能彻底改变NADES查,并简化生物活性化合物在液体配方中的使用.
- 该方法为推进绿色化学和制药行业提供了一个强大的工具.
相关概念视频
Transformers with Off-Nominal Turns Ratios
152
In scenarios involving parallel transformers with disparate ratings, developing per-unit models requires accommodating off-nominal turns ratios. This situation arises when the selected base voltages are not proportional to the transformer’s voltage ratings. Consider a transformer where the rated voltages are related by the term a. If the chosen voltage bases satisfy a relationship involving term b, term c is defined as the ratio of these bases. This ratio is then substituted into the...
152
Transformers
1.1K
A device that transforms voltages from one value to another using induction is called a transformer. A transformer consists of two separate coils, or windings, wrapped around the same soft iron core. However, they are electrically insulated from each other.
The iron core has a substantial relative permeability. Therefore, the magnetic field lines generated due to the current in one winding are almost entirely confined within the core, such that the same magnetic flux permeates each turn of both...
The iron core has a substantial relative permeability. Therefore, the magnetic field lines generated due to the current in one winding are almost entirely confined within the core, such that the same magnetic flux permeates each turn of both...
1.1K
Three-Winding Transformers
226
Three identical single-phase transformers can be configured to form a three-phase transformer connection, which involves high-voltage and low-voltage windings. The high-voltage windings are denoted by capital letters A-B-C, while the low-voltage windings are labeled with lowercase letters a-b-c, representing their respective phases. This notation helps distinguish between the high and low voltage sides of the transformer.
In the per-unit equivalent circuit of a grounded Y-Y three-phase...
In the per-unit equivalent circuit of a grounded Y-Y three-phase...
226
Types Of Transformers
976
Transformers can provide desired voltages to a circuit by modifying the number of turns in the secondary windings.
If the ratio of the number of turns in the secondary winding to that of the primary winding is greater than one, then the transformer is said to be a step-up transformer. In a step-up transformer, the voltage at the secondary winding is greater than the voltage applied at the primary winding.
However, if this ratio is less than one, the transformer is said to be a step-down...
If the ratio of the number of turns in the secondary winding to that of the primary winding is greater than one, then the transformer is said to be a step-up transformer. In a step-up transformer, the voltage at the secondary winding is greater than the voltage applied at the primary winding.
However, if this ratio is less than one, the transformer is said to be a step-down...
976
Equivalent Circuits for Practical Transformers
422
The practical equivalent circuits of single-phase two-winding transformers exhibit significant deviations from their idealized versions due to the inherent properties of winding resistance and finite core permeability. These properties result in real and reactive power losses, affecting the transformer's performance. Understanding these deviations is crucial for designing more efficient transformers.
In a practical transformer, each winding exhibits resistance and leakage reactance. The...
In a practical transformer, each winding exhibits resistance and leakage reactance. The...
422
Reducing Line Loss
152
In a three-phase circuit, line loss is an indicator of energy dissipated as heat due to the resistance of transmission lines. To address this, incorporating transformers into the system—a step-up transformer at the source and a step-down transformer at the load—is a strategic solution. Two three-phase transformers are introduced to improve this.
With a step-up transformer at the source, the voltage is increased, thereby reducing the current in the transmission lines since power loss...
With a step-up transformer at the source, the voltage is increased, thereby reducing the current in the transmission lines since power loss...
152