概括
这项研究引入了一种新的光谱辐射校准方法,以纠正衍射偏差引起的错误. 改进的技术准确地测量不完全填补光谱辐射计视野的目标.
科学领域:
- 光学工程是指光学工程.
- 计量学 计量学 计量学
背景情况:
- 光谱辐射计对于光谱辐射的测量至关重要.
- 标准校准方法引入部分填充视野 (FOV) 的错误,原因是未经纠正的衍射偏差.
研究的目的:
- 开发一种光谱辐射校准方法,以纠正衍射偏差因子.
- 为了提高对不完全占据FOV的目标的测量精度.
主要方法:
- 建立了一个使用聚合器,黑体和针孔来创建无限点源的系统.
- 改变了点源的撞击角度,以模拟不同的FOV.
- 在实验中校准了衍射偏差因子,证明了它们的光谱独立性.
主要成果:
- 拟议的方法纠正了光谱辐射测量的错误.
- 发现衍射偏差因子在光谱上是独立的.
- 该方法对各种形状的目标和部分FOV占用有效.
结论:
- 这种新的校准方法显著提高了光谱辐射计的准确性.
- 考虑衍射偏差因子对于使用部分填充的FOV进行精确测量至关重要.
相关概念视频
IR Spectrometers
1.1K
There are two main infrared (IR) spectrophotometers: dispersive IR spectrometers and Fourier transform infrared (FTIR) spectrometers. In a dispersive IR spectrometer, a beam of infrared radiation produced by a hot wire is divided into two parallel equal-intensity beams using mirrors. One beam passes through the sample, while another is a reference beam. The beams then move through the monochromator, which separates the radiations into a continuous spectrum of different frequencies. The...
1.1K
Spectrophotometry: Introduction
2.9K
Spectrophotometry is the quantitative measurement of the absorption, reflection, diffraction, or transmission of electromagnetic radiation through a material as a function of the intensity and wavelength of the radiation. A spectrophotometer is a device used to measure the change in the radiation intensity caused by its interaction with the material.
The essential components of a spectrophotometer include a source of electromagnetic radiation, a slot for placing a material to be analyzed, and a...
The essential components of a spectrophotometer include a source of electromagnetic radiation, a slot for placing a material to be analyzed, and a...
2.9K
Attenuated Total Reflectance (ATR) Infrared Spectroscopy: Overview
281
Attenuated total reflectance (ATR) infrared spectroscopy is a powerful analytical technique used to study the composition of materials. It is widely employed in chemistry, materials science, forensic science, and other fields where sample characterization is required. ATR has several advantages over traditional transmission IR spectroscopy, including the requirement of little to no sample preparation and the ability to analyze a wide range of samples.
The ATR process begins by directing a beam...
The ATR process begins by directing a beam...
281
Atomic Absorption Spectroscopy: Instrumentation
558
An atomic absorption spectrophotometer (AAS) comprises several components: a radiation source, an atomizer, a monochromator, and a detector. The radiation source can be a hollow-cathode lamp (HCL) or an electrodeless-discharge lamp (EDL), both of which provide a narrow emission line of the required wavelength. However, some instruments use continuum sources and high-resolution monochromators to achieve a narrow range of radiation.
The atomizer used in AAS can be either a flame atomizer or an...
The atomizer used in AAS can be either a flame atomizer or an...
558
UV–Vis Spectrometers
1.3K
The absorbance of UV and visible (UV–visible) radiations is measured using a UV–visible spectrophotometer. Deuterium lamps, which emit UV radiation, and tungsten lamps, which produce radiation in the visible region, are used as light sources in UV–visible spectrophotometers. A monochromator or prism is used for diffraction grating, i.e., to split the incoming radiation into different wavelengths. A system of slits is used to focus the desired wavelength on the sample cell.
1.3K
Raman Spectroscopy Instrumentation: Overview
294
A conventional Raman spectrophotometer includes a laser source, a sample holding system, a wavelength selector, and a detector.
The monochromatic laser source, typically using visible or near-infrared radiation, generates a highly focused beam of light. This light interacts with the molecules of the sample, scattering some of the light. Liquid and gaseous samples are usually tested in ordinary glass capillaries, while solids can be analyzed as powders packed in capillaries or as potassium...
The monochromatic laser source, typically using visible or near-infrared radiation, generates a highly focused beam of light. This light interacts with the molecules of the sample, scattering some of the light. Liquid and gaseous samples are usually tested in ordinary glass capillaries, while solids can be analyzed as powders packed in capillaries or as potassium...
294