Jove
Visualize
联系我们
JoVE
x logofacebook logolinkedin logoyoutube logo
关于 JoVE
概览领导团队博客JoVE 帮助中心
作者
出版流程编辑委员会范围与政策同行评审常见问题投稿
图书馆员
用户评价订阅访问资源图书馆顾问委员会常见问题
研究
JoVE JournalMethods CollectionsJoVE Encyclopedia of Experiments存档
教育
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab Manual教师资源中心教师网站
使用条款与条件
隐私政策
政策

相关概念视频

您也可能阅读

相关文章

通过共同作者、期刊和引用图与本文相关的文章。

排序
Same author

A cross-domain test battery for comprehensive hearing loss characterisation using functional, physiological, and vestibular measures.

International journal of audiology·2026
Same author

Functional hearing and low frequency hearing preservation after cochlear implant surgery is achievable with FLEX electrode arrays: Real world evidence from the MEHS Registry.

PloS one·2026
Same author

Radar Multiple Bin Selection for Breathing and Heart Rate Monitoring in Acute Stroke Patients in a Clinical Setting.

Sensors (Basel, Switzerland)·2026
Same author

Evaluation of Pre-Applied Conductive Materials in Electrode Grids for Longterm EEG Recording.

Sensors (Basel, Switzerland)·2025
Same author

Neuromodulatory Effects of Transcranial Pulse Stimulation (TPS) in Neurological and Psychiatric Disorders-A Systematic Review and Meta-Analysis.

Neurology international·2025
Same author

Machine Learning Versus Simple Clinical Models for Cochlear Implant Outcome Prediction.

Audiology research·2025

相关实验视频

Updated: May 10, 2025

Evaluation of an Exclusive Spur Dike U-Turn Design with Radar-Collected Data and Simulation
11:41

Evaluation of an Exclusive Spur Dike U-Turn Design with Radar-Collected Data and Simulation

Published on: February 1, 2020

20.2K

雷达生命信号监测的可行性使用多个范围 Bin 选择选择.

Benedek Szmola1,2,3, Lars Hornig3, Karen Insa Wolf3

  • 1Department of Neurology, School of Medicine and Health Science, Carl von Ossietzky Universität Oldenburg, 26129 Oldenburg, Germany.

Sensors (Basel, Switzerland)
|April 26, 2025
PubMed
概括

使用雷达进行非接触式生命体征监测,通过选择多个呼吸和心跳信号来增强. 与单个信号选择相比,这种方法提高了准确性并减少了工件.

关键词:
声中位数的中位数侧面放置的放置方式多个范围 bin 选择 bin 选择持久性图表是一个持久性图.雷达 雷达 雷达 雷达 是一个睡眠监测 睡眠监测 睡眠监测时间延迟嵌入式嵌入式拓学数据分析数据分析.监测生命体征,监测生命体征.

更多相关视频

Selecting Multiple Biomarker Subsets with Similarly Effective Binary Classification Performances
07:35

Selecting Multiple Biomarker Subsets with Similarly Effective Binary Classification Performances

Published on: October 11, 2018

7.4K
Design and Analysis for Fall Detection System Simplification
08:05

Design and Analysis for Fall Detection System Simplification

Published on: April 6, 2020

10.6K

相关实验视频

Last Updated: May 10, 2025

Evaluation of an Exclusive Spur Dike U-Turn Design with Radar-Collected Data and Simulation
11:41

Evaluation of an Exclusive Spur Dike U-Turn Design with Radar-Collected Data and Simulation

Published on: February 1, 2020

20.2K
Selecting Multiple Biomarker Subsets with Similarly Effective Binary Classification Performances
07:35

Selecting Multiple Biomarker Subsets with Similarly Effective Binary Classification Performances

Published on: October 11, 2018

7.4K
Design and Analysis for Fall Detection System Simplification
08:05

Design and Analysis for Fall Detection System Simplification

Published on: April 6, 2020

10.6K

科学领域:

  • 生物医学工程 生物医学工程
  • 医疗器械 医疗器械
  • 信号处理 信号处理

背景情况:

  • 雷达提供了有前途的非接触式生命体征监测.
  • 它们可以补充睡眠研究的多睡眠学.
  • 从多个身体部位同时提取生命体征是可能的.

研究的目的:

  • 介绍一种用于选择多个呼吸和心跳信号的新方法.
  • 使用并发信号来提高生命速率的稳定性和准确性.
  • 为了改善无接触式生命体征监测.

主要方法:

  • 从拓数据分析中开发了一个使用持久性图的算法.
  • 在持久性图表上评估多个标准,以检测生命信号.
  • 在夜间雷达和多重睡眠记录同时进行测试.

主要成果:

  • 多重信号选择改善了呼吸的准确性 (MAE 0.20与0.29呼吸/分钟).
  • 多重信号选择改善了心率的准确性 (MAE 0.66对比1.97次/分钟).
  • 选择了更少的人工细分,信号分布与生理学保持一致.

结论:

  • 无接触式生命体征监测的好处是通过多个信号选择提高了准确性.
  • 这种方法提高了稳定性,并减少了基于雷达的监控中的错误.