Jove
Visualize
联系我们
JoVE
x logofacebook logolinkedin logoyoutube logo
关于 JoVE
概览领导团队博客JoVE 帮助中心
作者
出版流程编辑委员会范围与政策同行评审常见问题投稿
图书馆员
用户评价订阅访问资源图书馆顾问委员会常见问题
研究
JoVE JournalMethods CollectionsJoVE Encyclopedia of Experiments存档
教育
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab Manual教师资源中心教师网站
使用条款与条件
隐私政策
政策

相关概念视频

Controlled-Current Coulometry: Coulometric Titration01:18

Controlled-Current Coulometry: Coulometric Titration

514
Coulometric titrations are a form of titrimetric analysis where the reagent is generated electrically, and its amount is evaluated based on current and generating time. The electron serves as the standard reagent. The procedure is similar to conventional titrations, such as endpoint detection.
The fundamental requirements for coulometric titrations are (1) 100% efficiency in the reagent-generating electrode reaction and (2) a stoichiometric and preferably rapid reaction between the generated...
514
Controlled-Current Coulometry: Overview01:27

Controlled-Current Coulometry: Overview

652
Controlled current coulometry, also known as amperostatic coulometry, is a technique used in electrochemical analysis to measure the quantity of a substance through the controlled passage of current. It involves the application of a constant current to an electrochemical cell containing the analyte of interest. As the current flows through the cell, the analyte undergoes a redox reaction at the electrode surface, resulting in a charge transfer. By monitoring the time required for a certain...
652
Differential Relays01:20

Differential Relays

734
Differential relays are used to protect generators, buses, and transformers by comparing electrical quantities at different points. When a fault occurs, the difference in current between the two points triggers the relay to operate, opening the circuit breaker. Under normal conditions, the current entering (i1) and leaving (i2) a generator are equal. When a fault occurs, however, these currents become unequal, and the difference current flows in the relay operating coil, causing the relay to...
734
Potentiometer01:30

Potentiometer

1.8K
Voltage and current measurements using a standard voltmeter and ammeter alter the circuit being measured either by drawing or resisting the current flow, which introduces uncertainties in the measurements. Null measurements balance the voltages so that no current flows through the measuring device and, therefore, no alterations occur in the measured circuit.
Suppose the emf of a battery needs to be measured. If the battery is directly connected to a standard voltmeter, the measured quantity is...
1.8K
Operational Amplifiers01:17

Operational Amplifiers

1.9K
The operational amplifier, often referred to as an op-amp, is a multifaceted building block of a circuit. This electronic component functions like a voltage-controlled voltage source and can also be used to create a voltage- or current-controlled current source. The design of an operational amplifier enables it to execute mathematical operations when external components like resistors and capacitors are linked to its terminals. An op-amp has the capacity to sum signals, amplify a signal,...
1.9K
Galvanometer01:25

Galvanometer

2.8K
Common devices, including car instrument panels, battery chargers, and inexpensive electrical instruments, measure potential difference (voltage), current, or resistance using a d'Arsonval galvanometer. This electromechanical instrument is also known as a moving coil galvanometer.
The galvanometer consists of  two concave-shaped permanent magnets, providing a uniform radial magnetic field in the annular region. In the center, a pivoted coil of fine copper wire is placed in the uniform...
2.8K

您也可能阅读

相关文章

通过共同作者、期刊和引用图与本文相关的文章。

排序
Same author

Fault Diagnosis Method for Excitation Dry-Type Transformer Based on Multi-Channel Vibration Signal and Visual Feature Fusion.

Sensors (Basel, Switzerland)·2025
Same author

Study on the Fast Transient Process of Primary Equipment Operation in UHV Fixed Series Capacitors Based on PEEC Method.

Sensors (Basel, Switzerland)·2025
Same author

Parameter Identification and Transition Process Online Calibration Method of Pulsed Eddy Current Receiving Coil Based on Underdamped Dynamic Response Characteristics.

Sensors (Basel, Switzerland)·2025
Same author

Multi-Modal Joint Pulsed Eddy Current Sensor Signal Denoising Method Integrating Inductive Disturbance Mechanism.

Sensors (Basel, Switzerland)·2025
Same author

Detection Method for Three-Phase Electricity Theft Based on Multi-Dimensional Feature Extraction.

Sensors (Basel, Switzerland)·2024
Same author

Regional Pulmonary Ventilation Assessment Method and System Based on Impedance Sensing Information from the Pentapulmonary Lobes.

Sensors (Basel, Switzerland)·2024

相关实验视频

Updated: Jan 18, 2026

High-precision Electromagnetic Flowmeter with Empty Pipe Detection via Complex Programmable Logic Device-based Waveform Recognition
05:11

High-precision Electromagnetic Flowmeter with Empty Pipe Detection via Complex Programmable Logic Device-based Waveform Recognition

Published on: June 27, 2025

658

高精度,宽比,自平衡电流比较器

Xue Wang1, He Li1, Hao Liu1

  • 1China Electric Power Research Institute, Wuhan 430074, China.

Sensors (Basel, Switzerland)
|September 13, 2025
PubMed
概括
此摘要是机器生成的。

一个新的自平衡电流比较器克服了磁性和电容性错误,用于高精度的电流比率校准. 该设备达到0.0002级准确度,提高了电气可追溯系统的效率.

关键词:
自动测量的自动测量目前的比较器当前比较器.自平衡的自我平衡.这是一个宽比例的宽度.在零流量流量.

更多相关视频

Measurement of Bioelectric Current with a Vibrating Probe
07:28

Measurement of Bioelectric Current with a Vibrating Probe

Published on: January 4, 2011

14.5K
Design and Application of a Fault Detection Method Based on Adaptive Filters and Rotational Speed Estimation for an Electro-Hydrostatic Actuator
06:45

Design and Application of a Fault Detection Method Based on Adaptive Filters and Rotational Speed Estimation for an Electro-Hydrostatic Actuator

Published on: October 28, 2022

2.1K

相关实验视频

Last Updated: Jan 18, 2026

High-precision Electromagnetic Flowmeter with Empty Pipe Detection via Complex Programmable Logic Device-based Waveform Recognition
05:11

High-precision Electromagnetic Flowmeter with Empty Pipe Detection via Complex Programmable Logic Device-based Waveform Recognition

Published on: June 27, 2025

658
Measurement of Bioelectric Current with a Vibrating Probe
07:28

Measurement of Bioelectric Current with a Vibrating Probe

Published on: January 4, 2011

14.5K
Design and Application of a Fault Detection Method Based on Adaptive Filters and Rotational Speed Estimation for an Electro-Hydrostatic Actuator
06:45

Design and Application of a Fault Detection Method Based on Adaptive Filters and Rotational Speed Estimation for an Electro-Hydrostatic Actuator

Published on: October 28, 2022

2.1K

科学领域:

  • 电气计量学 电气计量学
  • 仪器仪表与测量科学 仪器仪表与测量科学

背景情况:

  • 当前的比例标准设备对于当前的可追溯性至关重要.
  • 现有的设备存在磁性和电容性错误,限制了性能.
  • 对于先进的校准,需要高精度和广泛的变化比.

研究的目的:

  • 开发一种新型的宽变比自平衡电流比较器.
  • 为了解决当前比例标准设备中的磁性和电容性错误.
  • 为了提高电流比校准的效率和准确性.

主要方法:

  • 使用零磁流原理进行电流比较.
  • 集成的电子补偿技术与错误分析.
  • 开发了用于宽比转换的自平衡机制.
  • 进行错误性能的理论分析和实验校准.

主要成果:

  • 新的电流比较器实现了符合0.0002级要求的精度.
  • 在广泛的电流比率中表现出高精度.
  • 成功校准了0.001级以下的标准电流.
  • 在电流比校准测试中显著提高了工作效率.

结论:

  • 开发的宽变比自平衡电流比较器有效地减轻了磁性和电容性误差.
  • 这项创新为高精度,高效率的广域电流比率校准提供了解决方案.
  • 该设备增强了当前比例值的可追溯性系统.