Jove
Visualize
联系我们
JoVE
x logofacebook logolinkedin logoyoutube logo
关于 JoVE
概览领导团队博客JoVE 帮助中心
作者
出版流程编辑委员会范围与政策同行评审常见问题投稿
图书馆员
用户评价订阅访问资源图书馆顾问委员会常见问题
研究
JoVE JournalMethods CollectionsJoVE Encyclopedia of Experiments存档
教育
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab Manual教师资源中心教师网站
使用条款与条件
隐私政策
政策

相关概念视频

Amperometry: Overview01:10

Amperometry: Overview

2.2K
Amperometry is a technique commonly used to measure the concentration of specific analytes in a solution by monitoring the electric current generated during an electrochemical reaction. It involves applying a constant potential between a working electrode and a reference electrode to measure the resulting current, which is proportional to the concentration of the analyte. The Clark oxygen electrode operates based on this principle of amperometry. It consists of a cathode and an anode enclosed...
2.2K

您也可能阅读

相关文章

通过共同作者、期刊和引用图与本文相关的文章。

排序
Same author

Connexin 43 promotes stemness of leukemia cells and chemoresistance in T-cell acute lymphoblastic leukemia via the RAC1/AKT/GSK3β axis.

Chinese medical journal·2026
Same author

Patient-reported outcomes in chronic GVHD: instruments, clinical utility, and survivorship integration.

Journal of patient-reported outcomes·2026
Same author

CES1 deficiency is associated with metabolic reprograming and endothelial dysfunction in pulmonary arterial hypertension.

American journal of respiratory and critical care medicine·2026
Same author

Harnessing brassinosteroid signaling in rice: from molecular pathways to environmentally adaptive breeding.

Frontiers in plant science·2026
Same author

Hypofractionated Radiotherapy Induces ISG15<sup>+</sup>MHC-I<sup>+</sup> Neutrophils to Augment Anti-Tumor Immunity and Prime Immune Checkpoint Blockade Responses in Rectal Cancer.

Advanced science (Weinheim, Baden-Wurttemberg, Germany)·2026
Same author

Tick lipocalin triggers mammalian IGFBP-3-mediated apoptosis in macrophages and keratinocytes.

Frontiers in immunology·2026
Same journal

RETRACTED: Zhang et al. A Novel Framework for Reconstruction and Imaging of Target Scattering Centers via Wide-Angle Incidence in Radar Networks. <i>Sensors</i> 2025, <i>25</i>, 6802.

Sensors (Basel, Switzerland)·2026
Same journal

Enhancing Unsupervised Multi-Source Domain Adaptation for Person Re-Identification via Mixture of Experts and Graph-Based Relation.

Sensors (Basel, Switzerland)·2026
Same journal

Development of an Instrumented Glove for Palmar Pressure Assessment in Kayakers.

Sensors (Basel, Switzerland)·2026
Same journal

Development and Experimental Validation of an Autonomous IoT-Based Monitoring System for Real-Time Water Quality Assessment in the Amazon River.

Sensors (Basel, Switzerland)·2026
Same journal

Semi-Supervised Adversarial Learning Framework for Controller Area Network Bus Intrusion Detection.

Sensors (Basel, Switzerland)·2026
Same journal

Smart Optimization Method for Safety Signs in Innovative Manufacturing Environments Integrating Industrial Field IoT Sensors and Knowledge Graphs.

Sensors (Basel, Switzerland)·2026
查看所有相关文章

相关实验视频

Updated: May 3, 2026

Bridging the Bio-Electronic Interface with Biofabrication
16:38

Bridging the Bio-Electronic Interface with Biofabrication

Published on: June 6, 2012

17.2K

一个基于ZIF-8的高性能葡萄糖电化学检测平台,使用多层接口优化策略构建.

Canjie Hu1, Pengjia Qi1,2, Lichao Liu3

  • 1School of Information Science and Engineering (School of Cyber Science and Technology), Zhejiang Sci-Tech University, Hangzhou 310018, China.

Sensors (Basel, Switzerland)
|November 27, 2025
PubMed
概括
此摘要是机器生成的。

本研究介绍了一种使用MWCNTs/PB/ZIF-8@GOx/CS进行快速准确的葡萄糖检测的新型电化学葡萄糖生物传感器. 先进的传感器提供高灵敏度和稳定性,显示出对临床诊断和食品测试的巨大希望.

关键词:
戈克斯 (Gox) 的意思是说.在 MWCNTs 中.这里是ZIF-8的位置.电化学生物传感器葡萄糖检测 检测葡萄糖的检测

更多相关视频

Dry Film Photoresist-based Electrochemical Microfluidic Biosensor Platform: Device Fabrication, On-chip Assay Preparation, and System Operation
13:42

Dry Film Photoresist-based Electrochemical Microfluidic Biosensor Platform: Device Fabrication, On-chip Assay Preparation, and System Operation

Published on: September 19, 2017

12.4K
Development and Functionalization of Electrolyte-Gated Graphene Field-Effect Transistor for Biomarker Detection
07:51

Development and Functionalization of Electrolyte-Gated Graphene Field-Effect Transistor for Biomarker Detection

Published on: February 1, 2022

3.7K

相关实验视频

Last Updated: May 3, 2026

Bridging the Bio-Electronic Interface with Biofabrication
16:38

Bridging the Bio-Electronic Interface with Biofabrication

Published on: June 6, 2012

17.2K
Dry Film Photoresist-based Electrochemical Microfluidic Biosensor Platform: Device Fabrication, On-chip Assay Preparation, and System Operation
13:42

Dry Film Photoresist-based Electrochemical Microfluidic Biosensor Platform: Device Fabrication, On-chip Assay Preparation, and System Operation

Published on: September 19, 2017

12.4K
Development and Functionalization of Electrolyte-Gated Graphene Field-Effect Transistor for Biomarker Detection
07:51

Development and Functionalization of Electrolyte-Gated Graphene Field-Effect Transistor for Biomarker Detection

Published on: February 1, 2022

3.7K

科学领域:

  • 电化学 电化学 电化学
  • 生物传感器是一种生物传感器.
  • 材料科学 材料科学 材料科学

背景情况:

  • 准确的葡萄糖测定对于临床诊断和食品安全至关重要.
  • 现有的方法在速度,准确性和稳定性方面面临挑战.
  • 开发新的生物传感器是满足这些需求的必要条件.

研究的目的:

  • 开发一种高性能电化学葡萄糖生物传感器.
  • 为了利用多壁碳纳米管/普鲁士蓝/地质石石化伊米达酸框架-8@葡萄糖氧化酶/基托 (MWCNTs/PB/ZIF-8@GOx/CS) 进行增强的葡萄糖检测.
  • 在实际应用中评估传感器的性能特征.

主要方法:

  • 复合材料的制造,其中包括MWCNT,PB,ZIF-8,GOx和CS.
  • 制造的生物传感器的电化学表征.
  • 评估传感性能,包括线性范围,灵敏度,检测极限,可重复性和稳定性.

主要成果:

  • MWCNTs/PB导电网络增强了电子传输和催化活性.
  • ZIF-8为GOx固定提供了最佳的微环境,改善了酶活性和基质扩散.
  • MWCNTs/PB/ZIF-8@GOx/CS传感器表现出广泛的线性响应 (4.8 μM2.24 mM),高灵敏度 (579.57 μA/mM/cm2),低检测极限 (0.55 μM),优异的重复性 (RSD=1.49%),以及良好的存储稳定性 (86.23%在3周后).

结论:

  • 开发的电化学葡萄糖生物传感器在检测葡萄糖方面表现出卓越的性能.
  • MWCNT,PB,ZIF-8,GOx和CS的协同集成有助于增强传感能力.
  • 该传感器由于其精度,灵敏度和稳定性,显示出在临床诊断和食品测试中实际应用的巨大潜力.