,antoinsdiketopiperazines.

Maria-Aikaterini Giannakaki1, Marios Zingiridis1, Konstantinos G Froudas1

  • 1Department of Chemistry, University of Crete, Heraklion 700 13, Greece.

Organic letters
|January 30, 2026
PubMed
概括

我们开发了一个可扩展的mAUCy策略,用于快速合成 thiazolo hydantoins 和 diketopiperazines. 这种方法有效地在不到3小时内产生复杂的分子,适合多重克尺度.

相关概念视频

Transformations of Functions I01:29

Transformations of Functions I

A function's graph can be modified by changing its position or size without altering its overall shape. These transformations allow the graph to be moved across the coordinate plane while preserving its pattern and structure. One of the most common transformations is shifting, which repositions the graph without distorting it.When the output of a function is adjusted by adding or subtracting a constant, the graph shifts vertically. A positive value moves the graph upward, while a negative value...
197
Transformations of Functions II01:29

Transformations of Functions II

Transformations in mathematics alter the position or orientation of a function’s graph while preserving its fundamental shape. One important type of transformation is the horizontal shift, which involves modifying the input variable within a function’s equation. This operation affects where outputs occur along the horizontal axis but does not alter the function’s overall structure.A horizontal shift is achieved by replacing the input variable x with either x + c or x - c,...
169
Transformations of Functions III01:20

Transformations of Functions III

Transformations modify the graphical representation of a function without changing its fundamental form. One common transformation is reflection, which flips the graph across a designated axis. When the vertical coordinates of all points are multiplied by the negative one, the entire graph is mirrored over the horizontal axis. This transformation reverses the vertical orientation of peaks and troughs, akin to signal inversion in electrical systems, where a waveform is flipped, but the timing of...
203
Reclosers and Fuses01:26

Reclosers and Fuses

Automatic circuit reclosers enhance the protection of distribution circuits by interrupting and auto-reclosing an AC circuit according to a preset sequence. They effectively manage temporary faults on overhead distribution lines, often caused by tree limbs or wildlife, by briefly disrupting service to improve overall reliability. However, contact with reclosers or energized broken conductors on the ground can pose serious hazards.
A comprehensive protection scheme for radial distribution...
476
Bacterial Transformation01:33

Bacterial Transformation

In 1928, bacteriologist Frederick Griffith worked on a vaccine for pneumonia, which is caused by Streptococcus pneumoniae bacteria. Griffith studied two pneumonia strains in mice: one pathogenic and one non-pathogenic. Only the pathogenic strain killed host mice.
Griffith made an unexpected discovery when he killed the pathogenic strain and mixed its remains with the live, non-pathogenic strain. Not only did the mixture kill host mice, but it also contained living pathogenic bacteria that...
59.9K
Circuit Breaker and Fuse Selection01:23

Circuit Breaker and Fuse Selection

A circuit breaker is a device engineered to interrupt fault currents and sometimes reclose automatically. When a fault current is detected, the breaker separates the electrical contacts, which generates an arc. This arc is extinguished by methods such as elongation, cooling, or splitting, depending on the breaker's design. Breakers are categorized based on the voltage they operate at and the medium used for arc extinction, such as air, oil, SF6 gas, or vacuum.
In high-voltage systems,...