Jove
Visualize
联系我们
JoVE
x logofacebook logolinkedin logoyoutube logo
关于 JoVE
概览领导团队博客JoVE 帮助中心
作者
出版流程编辑委员会范围与政策同行评审常见问题投稿
图书馆员
用户评价订阅访问资源图书馆顾问委员会常见问题
研究
JoVE JournalMethods CollectionsJoVE Encyclopedia of Experiments存档
教育
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab Manual教师资源中心教师网站
使用条款与条件
隐私政策
政策

相关概念视频

Assessment of the Cardiovascular System II: Inspection01:29

Assessment of the Cardiovascular System II: Inspection

919
Inspection is the initial step in assessing the cardiovascular system. It involves a detailed visual examination that provides crucial information about a patient's circulatory and cardiac health. This systematic process, conducted from head to toe, helps identify signs of cardiovascular conditions by observing physical appearance, skin and mucous membranes, jugular and carotid pulsations, chest symmetry, and the condition of the extremities.
Head and Neck
919
Assessment of the Abdomen I: Inspection and Auscultation01:25

Assessment of the Abdomen I: Inspection and Auscultation

2.2K
Introduction
The abdominal examination is a cornerstone of clinical medicine, serving as a critical tool in diagnosing various gastrointestinal (GI) diseases. It involves a systematic approach that includes inspection and auscultation, each with distinct yet complementary roles in assessing the abdomen. This article will delve into these two primary methods healthcare professionals use to examine the abdomen.
Inspection of the Abdomen
The first step in any abdominal examination is inspection....
2.2K
Cardiovascular System Abnormal Findings I: Inspection and Palpation01:29

Cardiovascular System Abnormal Findings I: Inspection and Palpation

957
In a cardiovascular examination, inspection and palpation are crucial for identifying abnormalities.
Abnormal findings observed during an inspection
957
Nursing Assessment of the Genitourinary System II: Inspection and Palpation01:26

Nursing Assessment of the Genitourinary System II: Inspection and Palpation

904
The nursing assessment of the genitourinary (GU) system involves a systematic inspection and palpation to identify abnormalities in the kidneys, bladder, and surrounding structures.InspectionMouth: Inspect for signs of kidney dysfunction, such as stomatitis (inflammation of the mouth) and ammonia breath, which may occur in advanced kidney disease due to the buildup of urea, breaking down into ammonia.Skin: Check for pallor, which could indicate anemia caused by kidney disease. Look for...
904
Physical Assessment of the Respiratory Tract II: Inspection01:27

Physical Assessment of the Respiratory Tract II: Inspection

945
Physical assessment of the respiratory tract through inspection is a crucial step in understanding the patient's respiratory health. It provides insights into the functioning of the respiratory system, the musculoskeletal structure, and even the patient's nutritional status. This comprehensive approach involves observing several vital aspects: chest configuration, breathing patterns, respiratory rates, skin color, and use of accessory muscles.
Chest Configuration
The chest configuration...
945
Respiratory System Abnormal Finding I: Inspection and Percussion01:30

Respiratory System Abnormal Finding I: Inspection and Percussion

867
Respiratory system abnormalities are a significant concern in healthcare due to their potential to indicate underlying severe conditions like Chronic Obstructive Pulmonary Disease (COPD), asthma, and pneumonia. These abnormalities can often be detected through physical examination methods like inspection and percussion.
Inspection Findings
During an inspection, several findings may suggest the presence of respiratory distress or disease. Pursed-lip breathing, where exhalation is slowed by...
867

您也可能阅读

相关文章

通过共同作者、期刊和引用图与本文相关的文章。

排序
Same author

Dendritic Cell Served as Salvage Therapy for Advanced Hepatocellular Carcinoma Resistant to Tyrosine Kinase or Immune Checkpoint Inhibitors.

Cancers·2026
Same author

The albumin-bilirubin score predicts outcomes in advanced biliary tract cancer treated with durvalumab immunochemotherapy.

The oncologist·2026
Same author

Low-Dose Bevacizumab Maintains Efficacy With Reduced Adverse Events in Liver Cancer.

Liver international : official journal of the International Association for the Study of the Liver·2026
Same author

Prognostic Nutritional Index Predicts Outcomes in Hepatocellular Carcinoma Treated with Atezolizumab and Bevacizumab: A Propensity Score-matched Analysis.

Journal of clinical and translational hepatology·2026
Same author

Outcomes of Liver Transplantation Without Alcohol Abstinence in Alcohol-Associated Hepatitis With Original MELD Score ≥30.

Annals of transplantation·2026
Same author

A Diborylcarbazolyl Ligand for Stabilizing Low-Coordinate and Low-Valent Metal Complexes.

Inorganic chemistry·2026

相关实验视频

Updated: Feb 14, 2026

High-Accuracy Correction of 3D Chromatic Shifts in the Age of Super-Resolution Biological Imaging Using Chromagnon
08:18

High-Accuracy Correction of 3D Chromatic Shifts in the Age of Super-Resolution Biological Imaging Using Chromagnon

Published on: June 16, 2020

8.0K

快速推进轮配置检查使用色彩对焦传感器.

Bo-Huang Chang1,2, Tsung-Han Wu2, Wei-Chieh Chang2

  • 1Department of Mechanical Engineering, College of Engineering, National Yang Ming Chiao Tung University, Hsinchu 30010, Taiwan.

Sensors (Basel, Switzerland)
|February 13, 2026
PubMed
概括

这项研究引入了一个快速的,非接触式轮检查系统,使用染色共聚焦传感器 (CHCS). 该系统实现了实时质量控制的高精度,提高了生产效率并确保了产品质量.

关键词:
染色共聚焦传感器装备检查 装备检查在现场测量测量没有变形的轮轮形状.不接触式测量方式

更多相关视频

Hybrid Printing for the Fabrication of Smart Sensors
08:35

Hybrid Printing for the Fabrication of Smart Sensors

Published on: January 31, 2019

8.6K
NMR Spectroscopy as a Robust Tool for the Rapid Evaluation of the Lipid Profile of Fish Oil Supplements
08:54

NMR Spectroscopy as a Robust Tool for the Rapid Evaluation of the Lipid Profile of Fish Oil Supplements

Published on: May 1, 2017

26.9K

相关实验视频

Last Updated: Feb 14, 2026

High-Accuracy Correction of 3D Chromatic Shifts in the Age of Super-Resolution Biological Imaging Using Chromagnon
08:18

High-Accuracy Correction of 3D Chromatic Shifts in the Age of Super-Resolution Biological Imaging Using Chromagnon

Published on: June 16, 2020

8.0K
Hybrid Printing for the Fabrication of Smart Sensors
08:35

Hybrid Printing for the Fabrication of Smart Sensors

Published on: January 31, 2019

8.6K
NMR Spectroscopy as a Robust Tool for the Rapid Evaluation of the Lipid Profile of Fish Oil Supplements
08:54

NMR Spectroscopy as a Robust Tool for the Rapid Evaluation of the Lipid Profile of Fish Oil Supplements

Published on: May 1, 2017

26.9K

科学领域:

  • 机械工程 机械工程
  • 计量学 计量学 计量学
  • 制造业 制造技术 制造技术

背景情况:

  • 轮是关键的动力传输部件,需要有效的现场检查.
  • 传统的接触检查方法耗时,可能会损坏轮表面.

研究的目的:

  • 建立一个快速的,非接触式检测机制和装备检查模型.
  • 实现对轮制造工艺的实时监控,以提高效率和质量.

主要方法:

  • 开发一种快速,非接触式检测机制,使用色彩共聚焦传感器 (CHCS).
  • 在实时测量和监控的原型中实现完整的检查系统.
  • 检查结果与标准的无形螺杆轮牙形状模型进行比较.

主要成果:

  • 该CHCS实现了高速,非接触式测量,精度为1μm.
  • 被测试的合格轮 (GUTs) 的四分位数间范围在2.5微米内.
  • 胡须线值在10微米以内,证明了系统的有效性.

结论:

  • 开发的基于CHCS的系统为高精度的非接触式轮检查提供了可行的解决方案.
  • 实时监控能力提高了生产效率,并确保了产品质量.
  • 该方法允许在不移动轮的情况下进行检查,从而促进后续的完成过程.