Urinary lithium: distribution shape, reference values, and evaluation of exposure by inductively coupled plasma
1Department of Hygiene and Public Health, Osaka Medical College, Takatsuki City, Japan.
Abstract:
Inductively coupled plasma argon-emission spectrometry (ICPAES) was used to evaluate the lithium content of undiluted urine samples. The method can be performed with 1 mL of urine in a single tube using a routine ICPAES analysis for rapid and convenient assessment of lithium exposure in humans. Urine samples obtained from male workers (n = 86) who had not been exposed to lithium were used for the determination of this element by ICPAES. The obtained concentrations were corrected using a specific gravity of 1.024. The particular frequency distribution resulted in a log-normal distribution diagram for anatomical spread. Geometric mean value for urinary lithium in the nonexposed male workers was 23.5 microg/L, and the confidence interval from a log-normal distribution was 11.0 to 50.5 microg/L. Taking into consideration a short biological half-life and the massive urine excretion of lithium, urinary lithium was considered to be a useful index for monitoring of exposure. Calibration curves obtained for lithium standards had good sensitivity and linearity. Good reproducibility was assessed by lithium addition to urine samples. It was concluded that the obtained lithium reference values would be useful for the early diagnosis of lithium intoxication or in the assessment of the degree of exposure to lithium in subjects at risk.
More Related Videos
12:22Speciation and Bioavailability Measurements of Environmental Plutonium Using Diffusion in Thin Films
Published on: November 9, 2015
07:38Functional Characterization of Na+/H+ Exchangers of Intracellular Compartments Using Proton-killing Selection to Express Them at the Plasma Membrane
Published on: March 30, 2015
Related Concept Videos
Atomic Emission Spectroscopy: Lab
Atomic Emission Spectroscopy: Overview
Inductively Coupled Plasma Atomic Emission Spectroscopy: Principle
The ions and electrons produced interact with the fluctuating magnetic field created by a water-cooled...
Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used.
Flame Photometry: Lab
Atomic Absorption Spectroscopy: Radiation and Light Sources
Two common narrow-range 'line' sources used in AAS are hollow-cathode lamps (HCLs) and...