H J McDermott1, M R Dean, H Dillon
1Co-operative Research Centre for Cochlear Implant, Speech and Hearing Research, University of Melbourne, Australia. hugh@mail.medoto.unimelb.edu.au
Abstract:
To fit a hearing aid successfully, it is important to set the Saturated Sound Pressure Level (SSPL) or Maximum Power Output (MPO) appropriately. The SSPL should be low enough to prevent sounds from being amplified to uncomfortable loudness, and yet high enough to maximize speech intelligibility and signal quality. To help attain an optimum SSPL setting, a novel output compression limiting scheme, with shapable MPO (ShaMPO), has been devised. In ShaMPO, the SSPL is shaped across frequencies in accordance with the individual user's loudness discomfort levels (LDLs). The contributions of different frequency regions to loudness are controlled by summing the amplified signal power relative to the LDLs across frequencies, and using this signal to control a wideband compressor. This scheme and a conventional output compression limiting (AGCo) scheme have been implemented in a digital hearing aid. Ten subjects, with moderately-severe to profound sensorineural hearing losses, participated in a study comparing speech intelligibility and listening comfort for the two schemes. Results showed that there were no significant differences in the speech perception scores between AGCo and ShaMPO, even when the speech was presented at 80 dBA, at which level both schemes were in compression much of the time. However, an examination of how subjects selected the SSPL for the two schemes revealed that, in many instances, AGCo would permit some sounds with compact spectra to be amplified above LDL, whereas ShaMPO would not. Thus the ShaMPO scheme can improve listening comfort for some intense sounds without a loss of speech intelligibility. In contrast, half the subjects found speech at 80 dBA to be uncomfortably loud when listening through their own aids.
More Related Videos
06:04Systematic Hearing Performance Evaluation Process for Adolescents with Cochlear Implantation at Early Ages
Published on: March 24, 2023
08:19Controllable Nucleation of Cavitation from Plasmonic Gold Nanoparticles for Enhancing High Intensity Focused Ultrasound Applications
Published on: October 5, 2018
Related Concept Videos
Sound Intensity Level
The human ear can perceive an extensive range of sound intensity, necessitating the use of the logarithmic scale to define a physical quantity—the intensity level. It is a ratio of two intensities and hence a...
Frequency-Domain Interpretation of PD Control
The proportional control gain, combined with the system's...
Design Example: Vintage Mixing Console
The specifications for the pre-amplifier were clear. It needed to amplify the audio signal by a factor of 10, have an input impedance above 10...
Scaling
Time and frequency -Domain Interpretation of Phase-lag Control
Phase-lag controllers do not place a pole at zero, but instead influence the steady-state error by amplifying any finite,...
Load-frequency control