Dosimetry of the boron neutron capture reaction for BNCT and BNCEFNT
Related Experiment Video
Updated: Oct 20, 2026

Neutron Radiography and Computed Tomography of Biological Systems at the Oak Ridge National Laboratory's High Flux Isotope Reactor
Published on: May 7, 2021
J Burmeister1, C Kota, R L Maughan
1Gershenson Radiation Oncology Center, Karmanos Cancer Institute, Harper Hospital, Detroit, USA. burmeist@kci.wayne.edu
Abstract:
The use of paired proportional counters, constructed from A-150 tissue equivalent plastic (TEP) and A-150 TEP loaded with an appropriate amount of 10B (50 to 200 ppm), for the dosimetry of the boron neutron capture reaction has been investigated for several years at the Gershenson Radiation Oncology Center. This method has been used for determining the dose components (fast neutron, gamma ray and boron capture product dose) in both Boron Neutron Capture Therapy (BNCT) beams and in beams proposed for boron neutron capture enhancement of fast neutron therapy (BNCEFNT). A disadvantage of this method, when standard 1/2" diameter Rossi type proportional counters are used, is that the beam intensity must be relatively low in order to avoid saturation effects (pulse pile-up) in the counter. This is a major problem if measurements are to be made in a reactor beam, since reducing the beam intensity generally results in a change in the neutron spectrum. In order to overcome this problem, miniature cylindrical proportional counters have been developed which may be used in high intensity beams. The operational characteristics of these counters are compared with the standard 1/2" spherical counters. A further disadvantage of proportional counters is the relatively long time it takes to collect data, particularly if detailed information (depth-dose curves and beam profiles) is required. This problem could be overcome by using a set of ionization chambers (an A-150 TEP chamber, a Mg chamber and a Mg chamber with a 25 microns boron loaded inner wall) which can be scanned in a water phantom. After calibration against the paired proportional counters it should be possible to extract the fast neutron, gamma ray and boron neutron capture product doses from measurements made with these three ionization chambers. A set of such chambers has been used to make preliminary measurements in a fast neutron beam and the results of these measurements are presented.
More Related Videos
Related Concept Videos
Nuclear Transmutation
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...
Biological Effects of Radiation
Types of Radioactivity
Alpha (α) decay is the emission of an α particle from the nucleus. For example, polonium-210 undergoes α decay:
Radioactivity and Nuclear Equations
A nuclide of an element has a specific number of protons and...
Isotopes and Radioisotopes
An isotope containing more...