Related Experiment Videos
In vivo diffusion tensor imaging of rat spinal cord with echo planar imaging
1Department of Radiology, The University of Texas at Houston Medical School, Houston, Texas 77030, USA.
Abstract:
The in vivo apparent diffusion tensor (ADT) of spinal cord was measured in nine rats at 2.0 T using an interleaved multi-shot echo planar imaging (EPI) diffusion sequence. A technique that combines sliding acquisition and phase correction, based on a calibration scan, to reduce ghosting artifacts in the images introduced by the strong diffusion-sensitizing gradients was described. Two rotationally invariant parameters, the trace (actually trace/3, to be consistent with the published values) and the lattice anisotropy index (LAI) were estimated from the ADT. In in vivo cords, the mean white matter (WM) trace value (1.05 +/- 0.13 x 10(-3) mm(2)/sec) was found to be significantly higher than the gray matter (GM) trace (0. 84 +/- 0.12 x 10(-3) mm(2)/sec, p < 0.0025). Significant anisotropic diffusion was observed in both WM and GM, with greater anisotropy in the WM (LAI=0.59 +/- 0.04) than in the GM (LAI=0.47 +/- 0.06, p < 0. 0001). These results are in agreement with the in vivo values determined using the conventional spin-echo sequence. Magn Reson Med 42:300-306, 1999.