Percutaneous extraction of an abandoned coiled pacing lead
L Lickfett1, W Jung, L Pizzulli
1Department of Cardiology, University of Bonn, Germany.
Pacing and Clinical Electrophysiology : PACE
|August 24, 1999
Abstract:
Abandoning redundant pacing leads has been an accepted practice in most cases. Late migration of a lead is a rare, unpredictable, and potentially lethal complication of this approach and requires immediate removal. We report the case of an atrial pacing lead that had migrated and was found coiled in the right atrium. It was removed by a snare catheter via a femoral approach.