Effect of negative expiratory pressure on respiratory system flow resistance in awake snorers and nonsnorers
C Tantucci1, A Duguet, A Ferretti
1Clinica di Semeiotica Medica, University of Ancona, 60020 Ancona, Italy.
Abstract:
In spontaneously breathing subjects, intrathoracic expiratory flow limitation can be detected by applying a negative expiratory pressure (NEP) at the mouth during tidal expiration. To assess whether NEP might increase upper airway resistance per se, the interrupter resistance of the respiratory system (Rint,rs) was computed with and without NEP by using the flow interruption technique in 12 awake healthy subjects, 6 nonsnorers (NS), and 6 nonapneic snorers (S). Expiratory flow (V) and Rint,rs were measured under control conditions with V increased voluntarily and during random application of brief (0.2-s) NEP pulses from -1 to -7 cmH(2)O, in both the seated and supine position. In NS, Rint,rs with spontaneous increase in V and with NEP was similar [3.10 +/- 0.19 and 3.30 +/- 0.18 cmH(2)O x l(-1) x s at spontaneous V of 1.0 +/- 0.01 l/s and at V of 1.1 +/- 0.07 l/s with NEP (-5 cmH(2)O), respectively]. In S, a marked increase in Rint,rs was found at all levels of NEP (P < 0.05). Rint,rs was 3.50 +/- 0.44 and 8.97 +/- 3.16 cmH(2)O x l(-1) x s at spontaneous V of 0.81 +/- 0.02 l/s and at V of 0.80 +/- 0.17 l/s with NEP (-5 cmH(2)O), respectively (P < 0.05). With NEP, Rint,rs was markedly higher in S than in NS both seated (F = 8.77; P < 0.01) and supine (F = 9.43; P < 0.01). In S, V increased much less with NEP than in NS and was sometimes lower than without NEP, especially in the supine position. This study indicates that during wakefulness nonapneic S have more collapsible upper airways than do NS, as reflected by the marked increase in Rint,rs with NEP. The latter leads occasionally to an actual decrease in V such as to invalidate the NEP method for detection of intrathoracic expiratory flow limitation.
Related Concept Videos
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation (NIPPV)
Factors Affecting Pulmonary Ventilation
Alveolar Surface Tension
The alveolar fluid lines the luminal surface of the alveoli and exerts a force called surface tension. This force is caused by the polar water molecules in the liquid being more strongly attracted to each...
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Pressure Relationships in Thoracic Cavity
Breathing Mechanisms
Both intra-alveolar and intrapleural pressures rely on specific lung properties. The ability to breathe—allowing air to enter the lungs during...
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...
Respiratory Volumes and Capacities I