Related Experiment Video
Updated: Aug 18, 2026

High-Resolution Complexome Profiling by Cryoslicing BN-MS Analysis
Published on: October 15, 2019
Energy-sensitive cryogenic detectors for high-mass biomolecule mass spectrometry
M Frank1, S E Labov, G Westmacott
1Lawrence Livermore National Laboratory, V-Division, CA 94551, USA.
Abstract:
Energy-sensitive calorimetric detectors that operate at low temperatures ("cryogenic detectors") have recently been applied for the first time as ion detectors in time-of-flight mass spectrometry. Compared to conventional, ionization-based detectors, which rely on secondary electron formation or the charge created in a semiconductor, cryogenic detectors measure low-energy solid state excitations created by a particle impact. This energy sensitivity of cryogenic detectors results in several potential advantages for TOF-MS. Cryogenic detectors are expected to have near 100% efficiency even for very large, slow-moving molecules, in contrast to microchannel plates whose efficiency drops considerably at large mass. Thus, cryogenic detectors could contribute to extending the mass range accessible by TOF-MS and help improving detection limits. In addition, the energy resolution provided by cryogenic detectors can be used for charge discrimination and studies of ion fragmentation, ion-detector interaction, and internal energies of large molecular ions. Cryogenic detectors could therefore prove to be a valuable diagnostic tool in TOF-MS. Here, we give a general introduction to the cryogenic detector types most applicable to TOF-MS including those types already used in several TOF-MS experiments. We review and compare the results of these experiments, discuss practical aspects of operating cryogenic detectors in TOF-MS systems, and describe potential near future improvements of cryogenic detectors for applications in mass spectrometry.
More Related Videos
06:00Biological Samples Preparation for Speciation at Cryogenic Temperature using High-Resolution X-Ray Absorption Spectroscopy
Published on: May 27, 2022
06:42Cryogenic Sample Loading into a Magic Angle Spinning Nuclear Magnetic Resonance Spectrometer that Preserves Cellular Viability
Published on: September 1, 2020
Related Concept Videos
Electrospray Ionization (ESI) Mass Spectrometry
ESI utilizes electrical energy to transfer ions from the liquid phase of the sample into the...
High-Resolution Mass Spectrometry (HRMS)
Cryo-electron Microscopy
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Tandem Mass Spectrometry
High-Performance Liquid Chromatography: Types of Detectors