Clear corneal incisions enlarge after foldable intraocular lens (IOL) insertion. Forceps insertion of IOLs causes greater wound enlargement than injector insertion, with higher IOL powers showing more significant changes.
Area of Science:
- Ophthalmology
- Surgical Technology
- Biomaterials Science
Background:
- Foldable intraocular lenses (IOLs) are commonly implanted after cataract surgery.
- The method of IOL insertion can potentially influence the integrity of the clear corneal incision (CCI).
- Understanding incision dynamics is crucial for preventing wound-related complications.
Purpose of the Study:
- To quantify the change in incision size after foldable IOL implantation.
- To compare the effect of insertion method (forceps vs. injector) on CCI size.
- To evaluate the influence of IOL power on incision enlargement.
Main Methods:
- Phacoemulsification was performed on 100 patients, creating a clear corneal wound.
- Incision width was measured pre- and post-IOL implantation.
- Different types of foldable IOLs (silicone, acrylic) with varying optic diameters were inserted using either forceps or an injector.
Main Results:
- Forceps insertion of 5.5 mm optic diameter IOLs (silicone and acrylic) resulted in a 4.4-6.2% increase in wound size, dependent on IOL power.
- Injector insertion of silicone IOLs (5.5 mm and 6.0 mm optic diameters) caused a smaller wound enlargement of 3.2-3.3%.
- No significant difference in wound enlargement was observed with higher IOL powers when using an injector.
Conclusions:
- Clear corneal incisions predictably enlarge following foldable IOL insertion.
- Forceps insertion leads to greater incision enlargement compared to injector insertion.
- IOL power influences wound enlargement when using a forceps, but not with an injector.