Related Experiment Video
Updated: Jul 16, 2026

Large Scale Non-targeted Metabolomic Profiling of Serum by Ultra Performance Liquid Chromatography-Mass Spectrometry (UPLC-MS)
Published on: March 14, 2013
Quasi-linear gradients for capillary liquid chromatography with mass and tandem mass spectrometry
1Divisions of Biology, California Institute of Technology, Pasadena, CA 91125, USA.
Abstract:
Gradient elution, capillary liquid chromatography mass spectrometry was performed with linear, static gradients constructed by laminar flowing ten, 1.5 microL volume steps of decreasing organic concentration into tubing of small internal diameter. Sample loading, gradient formation, and sample elution were accomplished entirely by means of a commercially available micro-autosampler and single-syringe drive pump. The procedure was simple, fast, stable, and reproducible. Essentially linear gradients were produced without the use of additional valves, mixers, pumps or software. It took less than 10 minutes to form a gradient and less than 30 minutes to construct the set of individual buffer vials. The gradients were shown to be stable to storage. One hour after forming, peak retention times were reproduced to +/-0.5%. Long-term retention time reproducibility was found to vary by +/-2%. Chromatographic resolution was comparable or superior to that obtained by gradient elution with conventional dynamic mixing and split flow. The procedure was adapted with a 'peak parking' method which extended the time for generating peptide fragmentation data up to 10 minutes per peptide with the triple quadruple mass spectrometer. Using this technique, collision data were collected at the 25 femtomole level on nine of ten tryptic peptides in a single run.
More Related Videos
07:46Sheathless Capillary Electrophoresis–Mass Spectrometry for Metabolic Profiling of Biological Samples
Published on: October 1, 2016
14:42Liquid Chromatography Coupled to Refractive Index or Mass Spectrometric Detection for Metabolite Profiling in Lysate-based Cell-free Systems
Published on: September 23, 2021
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
High-Performance Liquid Chromatography: Elution Process
High-Performance Liquid Chromatography: Instrumentation
Electrophoresis: Overview
There...