Related Experiment Video
Updated: Oct 17, 2026

A High-throughput Automated Platform for the Development of Manufacturing Cell Lines for Protein Therapeutics
Published on: September 22, 2011
Bovine beta-lactoglobulin receptors on transformed mammalian cells (hybridomas MARK-3): characterization by flow
N S Palupi1, P Franck, C Guimont
1Laboratory of Medical Biochemistry-Prof. NABET, School of Medicine, University of Henri Poincare-Nancy I, 54505, Vandoeuvre, France.
Abstract:
Flow cytometry was used to demonstrate the presence of beta-lactoglobulin (betaLG) receptors on living murine hybridoma MARK-3 cells using a fluorescein isothiocyanate-betaLG conjugate (FITC-betaLG: molar ratio of 5:1). A site occupation curve was produced using a shift in the mean channel fluorescence at various concentrations of FITC-betaLG. The binding of labelled ligand was concentration dependent and was inhibited by unlabelled betaLG. The on-rate constant was 3.2x10(2) M(-1) min(-1) and the off-rate constant was 0.002 min(-1). Scatchard plot analysis gave a dissociation constant (K(d)) of 44+/-21x10(-7) and 39+/-24x10(-5) M (n=3). Flow cytometry indicated that at least 15% of the FITC-betaLG were internalized for 5 min and that internalization was temperature- and time-dependent. The internalization was confirmed by 3-D fluorescence microscopy (CELLScan system).