Related Experiment Video
Updated: Oct 17, 2026

Determination of Inorganic Arsenic in a Wide Range of Food Matrices using Hydride Generation - Atomic Absorption Spectrometry.
Published on: September 1, 2017
Optimized procedure for the determination of antimony in lipid-rich environmental matrices by flow injection hydride
1Research Centre Juelich, Environmental Specimen Bank, Germany.
Abstract:
An analytical procedure for the reliable determination of Sb in digests of lipid-rich environmental matrices in the low ng l-1-range based on flow injection hydride generation atomic absorption spectrometry (FI-HG-AAS) has been developed. Prior to HG-AAS, aliquots (250 to 320 mg) of dry samples were mineralized with 3 ml nitric acid and 0.5 ml of each sulfuric and perchloric acids in open digestion vessels made of glassy carbon in a heating block. Procedure detection and quantification limits of a previously developed procedure for the determination of Sb in plant materials by FI-HG-AAS were decreased with respect to the lower Sb concentrations in animal tissues, the sensitivity of the instrumental response was increased, and the composition of the acid digestion mixture was re-optimized for lipid-rich samples. The accuracy and precision of the developed procedure was evaluated by the analysis of the two reference materials Bovine Liver 1577a and Pig Kidney CRM 186. These reference materials have been additionally spiked with appropriate amounts of Sb to obtain recovery data. The solution detection limit (3 sigma) in digested samples was 0.021 microgram l-1, the detection limit for the whole procedure based on the dry powders was 7 pg g-1, the method quantification limit for a reliable determination of Sb was 23 pg g-1. The reproducibility of repetitive measurements was 6.0% at 0.1 microgram Sb l-1 and 2.2% at 0.5 microgram Sb l-1. Calibration curves were linear from 0.05 to 3 micrograms Sb l-1. To demonstrate the suitability of the developed method, concentrations of Sb have been determined in pigeon eggs (approximately 2 ng Sb g-1), as well as in bream livers (approximately 4 ng g-1) and in deer livers (approximately 5 to 8 ng g-1) from animals living in remote and urban-industrialized areas of Germany, respectively.
More Related Videos
06:00Biological Samples Preparation for Speciation at Cryogenic Temperature using High-Resolution X-Ray Absorption Spectroscopy
Published on: May 27, 2022
09:26Cellular Lipid Extraction for Targeted Stable Isotope Dilution Liquid Chromatography-Mass Spectrometry Analysis
Published on: November 17, 2011
Related Concept Videos
Atomic Absorption Spectroscopy: Lab
Solutions containing organic solvents, such as low-molecular-mass alcohols, esters, or ketones, enhance absorbances by increasing nebulizer...
Atomic Absorption Spectroscopy: Atomization Methods
Atomic Absorption Spectroscopy: Interference
Spectral interference occurs when signals from other elements or molecules overlap with the analyte signal, falsely elevating or masking the analyte's absorbance. This interference can be corrected using Zeeman,...
Atomic Absorption Spectroscopy: Overview
When irradiated by EMR of a particular wavelength, these...
Atomic Fluorescence Spectroscopy
Atomic Absorption Spectroscopy: Radiation and Light Sources
Two common narrow-range 'line' sources used in AAS are hollow-cathode lamps (HCLs) and...