Related Experiment Video
Updated: Aug 6, 2026

Safety Precautions and Operating Procedures in an (A)BSL-4 Laboratory: 2. General Practices
Published on: October 3, 2016
Applying a uniform layer of disinfectant by wiping
1Texwipe Company, Upper Saddle River, New Jersey, USA.
Abstract:
Disinfection or sterilization often requires applying a film of liquid to a surface, frequently done by using a wiper as the applicator. The wiper must not only hold a convenient amount of liquid, it must deposit it readily and uniformly. Contact time is critical to disinfection efficacy. Evaporation can limit the contact time. To lengthen the contact time, thickly applied layers are generally preferred. The thickness of such layers can be determined by using dyes or other tracers, as long as the tracers do not significantly affect the liquid's surface tension and viscosity and thus do not affect the thickness of the applied layer. Alternatively, as done here, the thickness of the layer can be inferred from the weight loss of the wiper. Results are reported of experiments on thickness of the layers applied under various conditions. Near saturation, hydrophilic polyurethane foam wipers gave layers roughly 10 microns thick, somewhat less than expected from hydrodynamic theory, but more than knitted polyester or woven cotton. Wipers with large liquid holding capacity, refilled often, should produce more nearly uniform layers. Higher pressures increase saturation in the wiper, tending to thicken the layer, but higher pressures also force liquid from the interface, tending to thin the layer, so the net result could be thicker or thinner layers, and there is likely to be an optimal pressure.
Related Concept Videos
Hand hygiene
Hand washing...
Cleaning, Sterilization, and Disinfection
Cleaning
The cleaning process usually involves using water with detergents or enzymatic cleaner and removing foreign material from objects and surfaces, including organic material such as body fluids or inorganic material like soil. Cleaning is performed before high-level disinfection and sterilization because foreign materials on the cover of the devices interfere with process...
Methods of Sterilization I: Physical Methods
Steam sterilization uses non-toxic, low-cost moist heat in the form of saturated steam under pressure, which is fast, microbicidal, and sporicidal, and quickly warms and penetrates fabrics. Autoclaves, or steam sterilizers, expose each item to direct steam contact for a predetermined time at the necessary...
Methods of Sterilization II: Chemical Methods
Using chemical sterilization rather than heat to clean out equipment is recommended. It eradicates and removes all bacteria,...
Physical Methods for Controlling Microbial Growth: Radiation and Filtration
Chemical Agents for Microbial Control

