[An immunoglobulin preparation as a calibrating agent for the gel filtration method]
T M Kargina1, R A Volkova, V Iu Gavrilenkova
1Tarasevich Research Institute for Standardization and Control of Medical Biological Preparations, Moscow, Russia.
The fractional composition of commercial immunoglobulin was studied by the method of gel filtration on ultragel AcA-34 and the possibility of its use for the calibration of a chromatographic column was shown. The fractionation of a specimen of IgG revealed the presence of 4 fractions. Their molecular weights corresponded to dimers, monomers, Fab fragments and low-molecular peptides. The qualitative fractional composition of the preparation was shown to be stable during 3 years of storage, as well as after keeping the preparation at 37 degrees C for 1 month. The attested characteristic of each IgG fraction, the distribution coefficient (Kav), was established. The use of a specimen of immunoglobulin obtained with the use of the modified Cohn's method--as calibrant will make it possible to calibrate the columns for a shorter period and to control the correctness of the analysis.
The fractional composition of commercial immunoglobulin was studied by the method of gel filtration on ultragel AcA-34 and the possibility of its use for the calibration of a chromatographic column was shown. The fractionation of a specimen of IgG revealed the presence of 4 fractions. Their molecular weights corresponded to dimers, monomers, Fab fragments and low-molecular peptides. The qualitative fractional composition of the preparation was shown to be stable during 3 years of storage, as well as after keeping the preparation at 37 degrees C for 1 month. The attested characteristic of each IgG fraction, the distribution coefficient (Kav), was established. The use of a specimen of immunoglobulin obtained with the use of the modified Cohn's method--as calibrant will make it possible to calibrate the columns for a shorter period and to control the correctness of the analysis.
More Related Videos
08:22Calibration-free In Vitro Quantification of Protein Homo-oligomerization Using Commercial Instrumentation and Free, Open Source Brightness Analysis Software
Published on: July 17, 2018
11:01Immunoglobulin G N-Glycan Analysis by Ultra-Performance Liquid Chromatography
Published on: January 18, 2020