Related Experiment Video
Updated: Oct 13, 2026

Drug-Induced Sleep Endoscopy (DISE) with Target Controlled Infusion (TCI) and Bispectral Analysis in Obstructive Sleep Apnea
Published on: December 6, 2016
[Auto-controlled continuous positive pressure in the titration and treatment of obstruction sleep disorders]
1Service d'Exploration Fonctionnelles Multidisciplinaires, Hôpital Antoine-Béclère, Clamart.
Abstract:
Self-adjusted Continuous Positive Airway Pressure or autoCPAP machines have been engineered to automatically adjust the pressure to maintain the upper airway patency. They can be used for titration or long-term home therapy. They have been developed to improve efficiency and compliance of CPAP treatment and the cost-effectiveness of titration and also to decrease the long waiting lists for manual titration. For the treatment, it is believed, but not demonstrated, that compliance may be increased by lowering the optimal pressure. Most machines are piloted by an algorithm based on detection of various combination of respiratory events such as apnoeas, hypopnoeas, snoring, inspiratory flow limitation or impedance. Several short-term studies have shown that autoCPAP reduces the indices of respiratory events and microarousals. In general, optimal CPAP determined automatically are identical or lower than evaluated manually by experienced technicians. However, the long-term benefits of auto-CPAP on compliance have not been determined and require further controlled clinical studies taking account not only compliance, but also sleep quality, quality of life, alertness and cognition for each autoCPAP. The cost-effectiveness of auto-titration versus conventional titration remains also to be established.
Related Concept Videos
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation (NIPPV)
Cardiopulmonary Resuscitation II: ACLS Airway Management
Mechanical Ventilation I: Indication and Settings
Sleep Apnea
The condition is more prevalent among...
Physiological Control of Respiration
Breathing, a seemingly passive process, is regulated by the respiratory center in the brainstem. This center coordinates the involuntary control of respirations, which means it occurs without conscious effort, ensuring a smooth and uninterrupted pattern.
Regulation of Ventilation
The body maintains ventilation by monitoring levels of carbon dioxide (CO2), oxygen (O2), and hydrogen ion concentration (pH) in the arterial blood. Among these factors, the level of CO2 plays a crucial...
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...