Gas Chromatography-Mass Spectrometry Paired with Total Vaporization Solid-Phase Microextraction as a Forensic Tool
Published on: May 25, 2021
Influence of fibre coating in headspace solid-phase microextraction-gas chromatographic analysis of aromatic and
1Dipartimento di Scienza e Tecnologia del Farmaco, Turin, Italy. bicchi@pharm.unito.it
Abstract:
Solid-phase microextraction (SPME) is a solvent-free technique, which is well established in headspace analysis since it is sensitive, because of the concentration factor achieved by the fibres, and selective, because of different coating materials which can be used. The performance of eight commercially available SPME fibres was compared to evaluate the recoveries of some characteristic components with different polarities and structures present in the headspace of four aromatic and medicinal plants: rosemary (Rosmarinus officinalis L.), sage (Salvia officinalis L.), thyme (Thymus vulgaris L.) and valerian (Valeriana officinalis L.). The relative concentration capacity of each fibre on the same components of each plant was also determined by comparing their abundance with that obtained by classical static-headspace GC. The partition coefficient, K1, between the headspace gaseous phase and SPME polymeric coating, and the relative concentration factors, of some of the characteristic components of the plant investigated dissolved in dibutyl phtalate, were also determined, under rigorously standardised analysis conditions. The results showed that the most effective fibres were those consisting of two components, i.e., a liquid phase (polydimethylsiloxane) and a porous solid (carboxen or divinylbenzene, or both).
Related Concept Videos
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a column.
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
Supercritical Fluid Chromatography
SFC utilizes a supercritical fluid mobile phase,...
Silica Gel Column Chromatography: Overview
Polar components tend to bind strongly to the silica gel, causing them to move slowly through the column. In contrast, nonpolar compounds...
Gas Chromatography: Sample Injection Systems
Two primary injection methods are used...