Related Experiment Video
Updated: Oct 10, 2026

Application of a New Mesh Fixation Method in Laparoscopic Incisional Hernia Repair
Published on: December 23, 2022
Tension-free hernia repair is associated with an increase in inflammatory response markers against the mesh
G Di Vita1, S Milano, M Frazzetta
1Department of Surgery, 2nd Division, University of Palermo, Palermo, Italy.
Background:
The purpose of this study was to evaluate the involvement of inflammatory mediators in patients undergoing Lichtenstein tension-free hernioplasty (LH) using polypropylene prosthetic materials or conventional Bassini hernia repair (BH).
Methods:
Thirty patients male with unilateral inguinal hernia without complications or recurrence were included in this study. Randomly, patients underwent LH or BH. Peripheral venous bloods samples were collected 24 hours prior to surgery and then 6, 24, 48 and 168 hours postoperatively.
Results:
We present evidences that LH patients showed a higher increased serum level of fibrinogen, C-reactive protein, alpha-1-antitrypsin, and interleukin-6 than BH patients. Postoperative visual analogue scales for pain were reduced on mobilization for patients undergoing LH compared with BH. Neutrophils were significantly increased only in LH compared with baseline. Ceruloplasmin, transferrin, and albumin levels were unmodified after BH or LH.
Conclusions:
In conclusion our data show that although LH induces less pain and more rapid postoperative recovery, it is associated with an higher inflammatory response compared with BH, likely due to polypropylene mesh.