Tilt Testing with Combined Lower Body Negative Pressure: a "Gold Standard" for Measuring Orthostatic Tolerance
Published on: March 21, 2013
Can stroke volume and cardiac output be determined reliably in a tilt-table test using the pulse contour method?
T Nieminen1, T Kööbi, V Turjanmaa
1Department of Clinical Physiology, Medical School, University of Tampere, Finland.
Abstract:
The applicability of the finger pressure-derived pulse contour (PC) technique was evaluated in the measurement of stroke volume (SV), cardiac output (CO) and their changes in different phases of the tilt-table test. The reference method was whole-body impedance cardiography (ICG). A total number of 40 physically active patients, aged 41 +/- 19 years, were randomly chosen from a pool of 230. Specifically speaking, 20 of the patients experienced (pre)syncope (tilt+ patients) during the head-up tilt (HUT), and 20 did not (tilt-). A total number of three measurement periods, 30-60 s each, were analysed: supine position, 5 min after the commencement of HUT, and 1 min before set down. SV and CO values measured by PC underestimated significantly those measured by ICG (biases +/- SD 19 +/- 14 ml and 1.55 +/- 1.14 l min-1, respectively) in agreement with earlier reports. The bias between the methods was almost the same in the different phases of the test. However, the SD of the bias was bigger for tilt+ (P < 0.05). When the bias between the methods was eliminated by scaling the first measurement to 100%, the agreement between the methods in the second and third measurements was clearly better than without scaling. Both methods showed a physiological drop in SV after the commencement of HUT. These results indicate that PC suffices in tracking the changes in CO and SV, but for absolute values it is not reliable.
Related Concept Videos
Pulse
Pulse Rate and its Significance
Pulse rate, often measured in beats per minute (bpm), reflects the heart rate (HR), which is influenced by numerous factors such as stress, physical activity, and hormonal changes. A normal resting adult pulse rate falls between...
Cardiac Output and Stroke Volume
In an average resting adult male, the typical cardiac output averages...
Cardiac Output II: Effect of Stroke Volume on Cardiac Output
Preload
Preload refers to the initial elongation of the cardiac myocytes before contraction and is related to the volume of blood filling the heart at the end of diastole, or end-diastolic volume. The...