Related Experiment Video
Updated: Oct 10, 2026

A Whole Body Dosimetry Protocol for Peptide-Receptor Radionuclide Therapy (PRRT): 2D Planar Image and Hybrid 2D+3D SPECT/CT Image Methods
Published on: April 24, 2020
The dosimetry for a coronary artery stent coated with radioactive 188Re and 32P
1Department of Medical Physics, Royal Perth Hospital, WA, Australia.
Abstract:
Radiation dose distributions have been calculated for 188Re and 32P activity on a coronary artery stent. The doses have been calculated both as a function of position along the stent and of depth into the artery wall. Comparisons of the dose from identical activities of 188Re and 32P on the stent show that the major differences arise from the different half-lives of the two activities. Coating the activity onto three surfaces of the stent rather than just the outside surface is found to reduce the dose by approximately 8 to 9%. Similarly, the effect of ignoring the attenuation in the stainless steel of the stent is to increase doses by 11 to 17%. Consideration is also given to the effect of the prolonged treatment times associated with a radioactive stent compared with the more common treatment over several minutes. It is shown that extended treatment may require between two and eight times the single dose to achieve the same effect depending on factors such as the radionuclide used, the dose required and the assumed cell survival curve. On the assumption that an instantaneous dose of 18 Gy at a depth of 1 mm into the artery would be required for successful prevention of neointimal hyperplasia, activities required for a stent coated with 188Re and 32P are tabulated.
Related Concept Videos
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Imaging Studies for Cardiovascular System V: CT
Isotopes and Radioisotopes
An isotope containing more...