A Coordinate System for Tumor Identification in Positron Emission Tomography (PET) Imaging
Erdi1, Srivastava, Humm
1Department of Medical Physics, Memorial Sloan-Kettering Cancer Center, 10021, New York, NY, USA
Abstract:
Purpose: PET can be useful in determining the progression of malignant disease over time as well as the response to therapy. To achieve this, the physician must be able to unambiguously identify and characterize individual tumors among several different scans.Methods: We have developed a coordinate system for identifying individual tumor sites on PET scans, selecting the carina on the transmission scan as a point of origin. Using this system, each tumor is given a set of spherical coordinates that identifies its position: a rho (rho, displacement from carina), a theta (θ, angle between the A-P axis and the tumor), and a phi (φ, angle between the polar axis and the tumor). We tested this method on a patient with metastatic thyroid cancer, who underwent 18FDG and 124I-Iodide PET scans in the same week. This sytem was also used on a patient with metastatic prostate cancer, who had two FDG scans done 7 weeks apart. The patient underwent chemotherapy treatment during this period, and the scans were performed to assess therapy response.Results: The patient with thyroid cancer had a total of 90 tumors, 82 of them identified in the 18FDG scan and 35 in the 124I-Iodide scan, with 27 tumors identified in both. For rho, θ, and φ among the 27 matching pairs of tumors, the mean differences were 6.80 +/- 5 mm, 6.22 +/- 4.54 degrees, and 5.51 +/- 5.81 degrees, respectively. The disparity in coordinate values between corresponding tumors can be explained by the distinctive uptake patterns of the radiopharmaceuticals. The patient with prostate cancer had 9 tumors identifiable in both the pre- and post-therapy scans. The mean differences for rho, θ, and φ among the 9 pairs of tumors were 1.93 +/- 1.65 mm, 6.67 +/- 5.53 degrees, and 2.04 +/- 2.02 degrees, respectively. After thorough analysis, we have determined that corresponding tumors with rho < 15 mm, θ and φ < 15 degrees difference usually indicate a match.Conclusion: This coordinate system facilitates the identification and characterization of individual tumors among multiple scans, thus aiding in both the assessment of diagnostic capabilities of different tracers, and the tracking of tumors following therapy.
More Related Videos
07:57Positron Emission Tomography-based Dose Painting Radiation Therapy in a Glioblastoma Rat Model using the Small Animal Radiation Research Platform
Published on: March 24, 2022
09:55Radiosynthesis, Quality Control, and Small Animal Positron Emission Tomography Imaging of 68Ga-Labelled Nano Molecules
Published on: October 4, 2024
Related Concept Videos
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET