Related Experiment Video
Updated: Jul 16, 2026

A Basic Positron Emission Tomography System Constructed to Locate a Radioactive Source in a Bi-dimensional Space
Published on: February 1, 2016
8. A Spherical Coordinate System for Tumor Identification in Positron Emission Tomography (PET) Imaging
Srivastava1, Erdi, Humm
1Department of Medical Physics, Department of Radiology, Nuclear Medicine Service, Memorial Sloan-Kettering Cancer Center, New York, NY, USA
Abstract:
Purpose: PET can be useful in determining the progression of malignant disease over time as well as the response to therapy. To achieve this, the physician must be able to unambiguously identify and characterize individual tumors among several different scans.Methods: We have developed a spherical coordinate system for identifying individual tumor sites on PET scans, using the carina on the transmission scan as a point of origin. Using this system, each tumor is given a set of spherical coordinates that identifies its position: a rho (rho, displacement from carina), a theta (θ, angle between the A-P axis and the tumor), and a phi (φ, angle between the cranial-caudal axis and the tumor).Results: We tested this method on a patient with metastatic thyroid cancer, who underwent 18FDG and 124I-Iodide PET scans in the same week. The patient had a total of 90 tumors, 82 of them identified in the 18FDG scan and 35 in the 124I-Iodide scan, with 27 tumors identified in both. For rho, θ, and φ among the 27 matching pairs of tumors, the mean differences were 6.80 + 5 mm, 6.22 + 4.54 degrees, and 5.51 + 5.81 degrees, respectively. After thorough analysis, we have determined that corresponding tumors with rho < 15 mm, θ and φ < 15 degrees difference usually indicate a match. The disparity in coordinate values between corresponding tumors can be explained by the distinctive uptake patterns of the radiopharmaceuticals.Conclusion: Within a mean difference of 6.8 mm and 6 degrees, this spherical coordinate system facilitates the identification and characterization of individual tumors among multiple scans, thus aiding in both the assessment of diagnostic capabilities of different tracers, and the tracking of tumors following therapy.
More Related Videos
07:57Positron Emission Tomography-based Dose Painting Radiation Therapy in a Glioblastoma Rat Model using the Small Animal Radiation Research Platform
Published on: March 24, 2022
09:55Radiosynthesis, Quality Control, and Small Animal Positron Emission Tomography Imaging of 68Ga-Labelled Nano Molecules
Published on: October 4, 2024
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET