Related Experiment Video
Updated: Jul 26, 2026

C-arm-Free Simultaneous OLIF51 and Percutaneous Pedicle Screw Fixation in a Single Lateral Position
Published on: September 16, 2022
Role of flexion-extension radiographs in blunt pediatric cervical spine injury
M E Ralston1, K Chung, P D Barnes
1Departments of Medicine, Division of Emergency Medicine, Children's Hospital, Harvard Medical School, Boston, MA, USA. meralston@mar.med.navy.mil
Objective:
To determine whether flexion-extension cervical spine radiography (FECSR) is abnormal in children who have sustained blunt cervical spine injury (CSI) when standard cervical spine radiography (SCSR) demonstrates no acute abnormalities.
Methods:
This was a blinded radiographic review of 129 patients < or = 16 years of age evaluated at an academic pediatric trauma center during July 1990-March 1996. All patients had SCSR (anteroposterior/lateral views) and FECSR performed for a trauma-related event within seven days of injury.
Results:
Of 46 patients without acute abnormalities on SCSR, one patient (with final clinical diagnosis of "no CSI") had acute abnormalities on FECSR (95% CI = 0.06% to 11.5%). Of 50 patients with isolated loss of lordosis on SCSR, no patient had acute abnormalities on FECSR (95% CI = 0% to 5.8%). The FECSR review revealed no acute abnormalities in 75 of 83 patients (90.4%) with suspicious findings for CSI viewed on SCSR (95% CI = 81.9% to 95.7%). Complications during FECSR were noted in one patient with transient paresthesias (0.8%) (95% CI = 0.02% to 4.2%).
Conclusions:
In children who underwent acute radiographic evaluation of blunt cervical spine trauma, FECSR was unlikely to be abnormal when no acute abnormality or isolated loss of lordosis was evident on SCSR. In a subset of patients with suspicious findings for occult CSI on SCSR, FECSR was useful in ruling out ligamentous instability in the acute, posttrauma setting.
More Related Videos
04:19Minimally Invasive Treatment for Thoracolumbar Burst Fracture Using Sagittal Alignment Screws and A Trauma Reduction Device
Published on: November 8, 2024
07:12Clinical Efficacy of an Innovative Multidimensional Traction Therapy in Moderate Adolescent Idiopathic Scoliosis
Published on: February 10, 2026
Related Concept Videos
X-ray Imaging
Fractures: Bone Repair
Minor fractures with no bone displacement are treated by immobilizing the fractured bone using a cast or splint. However, in the case of fractures with displaced bones, the broken bones are repositioned before immobilization to ensure successful healing without deformation and loss of function. The realignment of fractured bone ends is performed through a process called reduction. If the procedure...
Articulations of the Vertebral Column
Flail Chest-II
Assessment:
1. Clinical Evaluation:
History:
Radiological Investigation I: X-ray and CT