Oxygen transfer rate estimation in oxidation ditches from clean water measurements
A Abusam1, K J Keesman, K Meinema
1Systems and Control Group, Department of Agricultural, Environmental and Systems Technology, Wageningen University, Bomenweg 4, 6703 HD Wageningen, Netherlands. abdallah.abusam@user.aenf.wau.nl
Abstract:
Standard methods for the determination of oxygen transfer rate are based on assumptions that are not valid for oxidation ditches. This paper presents a realistic and simple new method to be used in the estimation of oxygen transfer rate in oxidation ditches from clean water measurements. The new method uses a loop-of-CSTRs model, which can be easily incorporated within control algorithms, for modelling oxidation ditches. Further, this method assumes zero oxygen transfer rates (KLa) in the unaerated CSTRs. Application of a formal estimation procedure to real data revealed that the aeration constant (k = KLaVA, where VA is the volume of the aerated CSTR) can be determined significantly more accurately than KLa and VA. Therefore, the new method estimates k instead of KLa. From application to real data, this method proved to be more accurate than the commonly used Dutch standard method (STORA, 1980).