Related Experiment Videos
[Difficult reintubation during a Fantoni's tracheostomy resolved using a laryngeal mask]
1Département d'anesthésie, réanimation et urgences, hôpital d'Instruction des Armées Clermont-Tonnerre, rue du Colonel Fonferrier, BP 41, 29200 Brest, France.
Annales Francaises D'Anesthesie Et De Reanimation
|June 8, 2001
Abstract:
We report the failure of a reintubation under direct laryngoscopy, during a percutaneous tracheostomy by Fantoni method. After the accidental per-procedural extubation and in front of an unpredicted difficult conventional endotracheal intubation, a laryngeal mask was used as an airway intubator conduit for the blind passage of the set's ventilation tube. This ventilation tube is a 40 cm long, 4 mm internal diameter special catheter with low pressure cuff, included into the TLT kit. The end of the procedure was uneventful.