Reliability and sensitivity of joint space measurements in hand radiographs using computerized image analysis
The Journal of Rheumatology
|August 18, 2001
Summary
Radiographic measurements of proximal interphalangeal (PIP) and metacarpophalangeal (MCP) joint spaces in healthy individuals are reliable. Averaging measurements across fingers improves sensitivity, detecting changes as small as 0.05 mm.
Area of Science:
- Radiology
- Orthopedics
- Rheumatology
Background:
- Accurate measurement of joint space width is crucial for assessing joint health and disease progression.
- Standard clinical radiographs are widely used, but their sensitivity to subtle changes requires validation.
Purpose of the Study:
- To determine the sensitivity and reliability of proximal interphalangeal (PIP) and metacarpophalangeal (MCP) mean joint space measurements from standard clinical radiographs.
- To establish the threshold for detecting actual changes in joint size based on radiographic measurements in healthy subjects.
Main Methods:
- Repeat hand radiographs of healthy subjects were obtained using standard techniques at 3-5 day intervals.
- Measurements were taken with hands in a flat position and in various flexed positions.
- Custom software was used for mean joint space determination, with manual validation and analysis of variance for reproducibility.
Main Results:
- In standard positions, changes > 0.11 mm (approx. 7%) indicate a physical change in joint space width (95% probability).
- Averaging across fingers reduces the detectable change to 0.05 mm (approx. 3%).
- Radiographic joint space increased with MCP flexure and decreased with PIP flexure.
Conclusions:
- Mean finger joint space measurements from standard radiographs are reliable and sensitive in healthy subjects, even with minor hand position variations.
- Further research is needed to ascertain if joint space changes in arthritis patients over 6-12 months exceed these detectable limits.