Principal component analysis of polarity and interaction parameters in inverse gas chromatography
K Héberger1, K Milczewska, A Voelkel
1Institute of Chemistry, Chemical Research Center, Hungarian Academy of Sciences, Budapest. heberger@chemres.hu
Abstract:
Inverse gas chromatography is used in the characterization of aliphatic-aromatic and aromatic ketones, their oximes, and ketone-oxime or oxime-oxime mixtures. All these organic materials are used as liquid stationary phases in gas chromatographic columns. A series of polarity and Flory-Huggins interaction parameters are determined and used to describe the physicochemical properties of examined materials, metal extractants, and products of their degradation. Principal component analysis (PCA) is performed on a data matrix consisting of polarity and interaction parameters for ketones, their oximes, and mixtures. The calculations are carried out on the correlation matrix. It is found that seven principal components account for more than 95% of the total variance in the data, indicating that the polarity (interaction) parameters are not correlating well. Physical meanings are attributed to the principal components, the most influential ones being that the first and the second principal components account for several Flory-Huggins interaction parameters, whereas the fifth is correlated with criterion "A". The plots of component loadings show characteristic groupings of polarity indicators, whereas that of component scores show several groupings of stationary phases. Cluster analysis provides mainly the same groupings. PCA allows for the grouping of polarity and solubility parameters based on the information carried within those parameters. There is no need to use more than one parameter from each cluster. McReynolds polarity and the partial molar excess Gibbs free energy of solution per methylene group carry the same information. The groups of ketones, oximes, and their mixtures can be distinguished with the use of PCA on the basis of the measured polarity, solubility parameters, or both.
More Related Videos
11:18A Practical Guide on Coupling a Scanning Mobility Sizer and Inductively Coupled Plasma Mass Spectrometer (SMPS-ICPMS)
Published on: July 11, 2017
10:14Chromatographic Fingerprinting by Template Matching for Data Collected by Comprehensive Two-Dimensional Gas Chromatography
Published on: September 2, 2020
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...
Inductively Coupled Plasma–Mass Spectrometry (ICP–MS): Overview
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a column.
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography: Types of Detectors-II