Real-time Breath Analysis by Using Secondary Nanoelectrospray Ionization Coupled to High Resolution Mass Spectrometry
Published on: March 9, 2018
Analysis of volatile sulphur compounds in breath by gas chromatography-mass spectrometry using a three-stage
N Ochiai1, M Takino, S Daishima
1Yokogawa Analytical Systems Inc., Osaka, Japan. nobuo_ochiai@agilent.com
Abstract:
A method for the determination of trace volatile sulphur compounds (VSCs) including methanethiol, dimethyl sulfide (DMS) and dimethyl disulfide (DMDS) at low ppbv (volume/volume) in breath has been developed using a large volume preconcentration technique prior to capillary GC-MS analysis. The breath sample was collected in a 6-1 fused-silica-lined stainless steel canister and introduced into the three-stage cryogenic trapping preconcentration system by GC-MS in the total ion monitoring (scan) mode. The water condensation effect of breath sample inside the canister, which is due to the difference between human body temperature and laboratory temperature, was examined. The condensed water in the fused-silica-lined canister at 24 degrees C did not affect the recoveries of VSCs within 12 h. As this three-stage cryogenic trapping preconcentration technique made it possible to remove excess water [relative humidity (RH) >95%] and carbon dioxide (3.8%) without loss of the VSCs, more than 400 ml of the breath sample could be concentrated. The detection limits of methanethiol, DMS and DMDS in a breath sample using this method were 0.13, 0.09 and 0.15 ppbv, respectively.
More Related Videos
05:29Profiling Volatile Compounds in Blackcurrant Fruit using Headspace Solid-Phase Microextraction Coupled to Gas Chromatography-Mass Spectrometry
Published on: June 9, 2021
05:22Rapid Collection of Floral Fragrance Volatiles using a Headspace Volatile Collection Technique for GC-MS Thermal Desorption Sampling
Published on: December 10, 2019
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a column.
Volatilization
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Gas Chromatography: Sample Injection Systems
Two primary injection methods are used...
Supercritical Fluid Chromatography
SFC utilizes a supercritical fluid mobile phase,...